![Fuji Electric FVR-C11S-7EN Series Instruction Manual Download Page 103](http://html1.mh-extra.com/html/fuji-electric/fvr-c11s-7en-series/fvr-c11s-7en-series_instruction-manual_2341873103.webp)
13 Electromagnetic Compatibility (EMC)
13-4
FVR-C11S-EN
13
Fig. 13-3-2
Recommended installation detail inside the enclosure (SW7 set to P24)
12
V
U
W
13
FWD
11
X1
REV
P24/CM
X3
30C
30B
30A
X2
L1/L
L2/N
P1
P(+) N(-)
P(+)
M
FM
C1
G
N
N
L
G
L
3
When power-factor correcting
DC reactor is used.
Metal Wiring
Cabinet
Motor
Power supply
1-phase
200 to 240V
50/60Hz
RFI Filter
Frequency setting voltage input
(0 to +10VDC)
Frequency setting current
input (+4 to +20mADC)
Forward operation
command
Reverse
operation
command
In case of speed control cable,
fix a part of shield by a cramp
as well motor power cable.
Alarm output
for any fault
To 11 terminal
Analog meter
Analog
monitor
In case of motor power
cable, fix a part of shield by
a cramp.