5-15
(H codes continued)
Code
Name
Data setting range
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
H89
Electronic Thermal
Overload Protection for
Motor
(Data retention)
0: Disable
1: Enable
–
–
Y
Y
1
–
H91
PID Feedback Wire
Break Detection
(Terminal [C1])
0.0: Disable alarm detection
0.1 to 60.0: After the specified time, cause
alarm
0.1
s
Y
Y
0.0
H92
Continuity of
(P)
Running *1
0.000 to 10.000 times; 999
0.001
times
Y
Y1
Y2
999
H93
(I)
0.010 to 10.000 s; 999
0.001
s
Y
Y1
Y2
999
H94
Cumulative Run Time of
Motor 1
0 to 9999 (in units of 10 hours)
–
–
N
N
–
5-76
H95
DC Braking
0: Slow
–
–
Y
Y
ACU:0
E:1
5-37
(Braking response
mode)
1: Quick
H96
STOP Key Priority/Start
Check Function
Data STOP key priority Start check function
–
–
Y
Y
ACE:0
U:3
–
0:
Disable
Disable
1:
Enable
Disable
2:
Disable
Enable
3:
Enable
Enable
H97
Clear Alarm Data
0: Disable
1: Clear alarm data
–
–
Y
N
0
5-74
H98
Protection/Maintenance
Function
0 to 31 (Decimal, Underlined part is the
default setting.)
Bit 0: Lower the carrier frequency
automatically (0: Disable; 1: Enable)
–
–
Y
Y
19
(Decimal)
5-76
(Mode selection) Bit 1: Detect input phase loss
(0: Disable; 1: Enable)
Bit 2: Detect output phase loss
(0: Disable; 1: Enable)
Bit 3: Select life judgment threshold of DC
link bus capacitor
(0: Factory default level;
1: User setup level)
Bit 4: Judge the life of DC link bus capacitor
(0: Disable; 1: Enable)
(Note) Alphabets in the Default setting field denote shipping destination: A (Asia), C (China), E (Europe) and U (USA).
*1 Available in the ROM version 0500 or later.