- 42 -
INZ-TN1ZSS-E
Note
Set the value so that H-Limit is larger than L-Limit, and that (H-Limit – L-Limit) is larger than hysteresis
width.
6.3.3 Analog output / alarm record
Set the recording range of the external alarm output such as analog output or the alarm record.
Setting range can be selected from “H-Limit”, “L-Limit” and “H/L Limit”. When there are two ranges, the
setting range can be selected from the 6 types of Range1 and Range2.
Note
When “OFF” is set to the ON/OFF setting of the alarm value, “Analog Output / Alarm Record” cannot be
set. Select “ON” again. The alarm output which is outside the range of High/Low limit cannot be per-
formed for 10 minutes after turning on the power.