700-G6-DB- Man Rev. 1 dft5 11 Feb 2021
Page 47/65
6.5.11
READ FORWARD POWER
Syntax:
RFWD
Access level: USER
Tx State:
Enabled/Disabled
Returns the current forward power in dBm. This value is updated at the bit rate when transmitting
and every 30 seconds when not transmitting.
6.5.12
READ REFLECTED POWER
Syntax:
RRFL
Access level: USER
Tx State:
Enabled/Disabled
Returns the reflected power in dBm. This value is updated at the bit rate when transmitting and
every 30 seconds when not transmitting.
6.5.13
READ POWER SUPPLY
Syntax:
RPS
Access level: USER
Tx State:
Enabled/Disabled
Returns the power supply voltage in Volts. This value is updated at the bit rate when transmitting
and every 30 seconds when not transmitting.
6.5.14
READ TCXO TEMPERATURE
Syntax:
RTEMP
Access level: USER
Tx State:
Enabled/Disabled
Returns the TCXO temperature (PCB temperature) in degrees Celsius. This value is updated at the
bit rate when transmitting and every 30 seconds when not transmitting.
6.5.15
READ MEASURED FREQUENCY
Syntax:
RMF
Access level: TECHNICIAN
Tx State:
Enabled/Disabled
This command returns the last measured OCXO and TCXO frequencies in the following format:
F-OCXO: 10000005.9000
F-TCXO: 43199.9166
Units are Hz.