700-G6-DB- Man Rev. 1 dft5 11 Feb 2021
Page 34/65
This command sets the channel number (
ccc
) for timed transmissions.
CCC
is the channel number
and has a valid range of 0 – 266 for bit rates of 100 and 300 BPS, and a range of 0 – 133 for a bit rate
of 1200 BPS.
For 100 BPS operations on channels 201-266, the transmitter will be configured for International
operation. Specifically, the 31-bit International EOT will be used (0x63CADD04) in place of the ASCII
EOT, and the preamble will be forced to Long.
Setting the channel number to 0 will disable timed transmissions.
6.3.3
SET SELF-TIMED TRANSMISSION BIT RATE
Syntax:
TBR=bbbb
Access level: USER
Tx State:
Disabled
This command sets the timed transmission bit rate where
bbbb
is the bit rate parameter and has
valid values of 100, 300 and 1200 BPS.
6.3.4
SET SELF-TIMED TRANSMISSION INTERVAL
Syntax:
TIN=dd:hh:mm:ss
Access level: USER
Tx State:
Disabled
Set interval between timed transmissions to days, hours, minutes, seconds specified in dd:hh:mm:ss
format. Valid range is 00:00:05:00 to 30:23:59:59.
6.3.5
SET SELF-TIMED TRANSMISSION FIRST TRANSMISSION TIME
Syntax:
FTT=hh:mm:ss
Access level: USER
Tx State:
Disabled
Set the time for the first timed transmission of the day. Valid range is 00:00:00 to 23:59:59.
6.3.6
SET SELF-TIMED TRANSMISSION TRANSMIT WINDOW LENGTH
Syntax:
TWL=xxx
Access level: USER
Tx State:
Disabled
Set the length of the timed transmit window. Length is specified in seconds. Valid range is 5 to 240
seconds.