RHT-XS Transmitter 

INSTRUCTIONS MANUAL - V2.0x 

                 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for RHT-XS

Page 1: ...NOVUS AUTOMATION 1 7 RHT XS Transmitter INSTRUCTIONS MANUAL V2 0x ...

Page 2: ... module the user has access to the two fixing holes as shown in the figure below Figure 1 Electronic module dimensions Figure 2 Fixing holes The figure below shows the dimensions of the remote sensor module Figure 3 Remote sensor module dimensions mm 2 2 ELECTRICAL INSTALLATION The transmitter can be ordered as 4 20 mA current output or 0 to 10 Vdc voltage output The output signal type is defined ...

Page 3: ...plan If possible in grounded conduits The instrument supply must come from a network proper for instrumentation In control and monitoring applications it is essential to consider what may happen when any part of the system fails It is recommended to use RC FILTERS 47 Ω and 100 nF series in parallel with coils of contactors and solenoids etc CARE WITH THE SENSORS The calibration of the humidity sen...

Page 4: ...dity and temperature measurement ranges indicating a Lower Limit value and an Upper Limit value The defined range cannot exceed the Sensor Measuring shown in this same field and also cannot establish a range with a span less than the Minimum Range indicated below in this same field When the Lower Limit is set to a value higher than the Upper Limit the output current has a decreasing behavior 20 4 ...

Page 5: ... the RHT XS and transmit the dew point instead of relative humidity you must follow the steps below Connect the device to the TxConfig interface and run the software The software will recognize the RHT XS model read its configuration and make it available to the user In the Options menu enter Humidity Reading Type only available when an RHT XS model is detected and select the Dew Point option At t...

Page 6: ...solation between loops The 4 20 mA outputs are isolated from each other The 0 10 V is not isolated from each other Provides protection against power supply polarity inversion Yes Protection Electronic circuit case IP65 Sensors capsule IP40 Cable entrance Compress fitting PG7 Operating limits Sensor RHT XS See Figure 12 Electronic circuit Electronic circuit RHT XS Operating temperature 10 to 65 C 1...

Page 7: ...NOVUS AUTOMATION 7 7 5 WARRANTY Warranty conditions are available on our website www novusautomation com warranty ...