700-G6-DB- Man Rev. 1 dft5 11 Feb 2021
Page 39/65
One minute prior to transmission data is removed from the transmit buffer and encoded for
transmission (The Data In Buffer LED will go out). If this command is received within 1 minute of the
transmission time or during a timed transmission, the data will not be included in the current
transmission but will be buffered for the next interval.
6.4.4
GET THE LENGTH OF THE MESSAGE IN THE TIMED TRANSMISSION BUFFER
Syntax:
TML
Access level: USER
Tx State:
Enabled/Disabled
Returns the number of bytes stored in the timed transmission buffer.
6.4.5
GET THE MAXIMUM TIMED MESSAGE LENGTH
Syntax:
MTML
Access level: USER
Tx State:
Enabled
Returns the maximum number of bytes that can be transmitted with the current timed transmission
bit rate, window length and preamble type.
6.4.6
CLEAR THE TIMED TRANSMISSION BUFFER
Syntax:
CTB
Access level: USER
Tx State:
Enabled/Disabled
Clears the timed transmission buffer.
6.4.7
RANDOM TRANSMISSION MESSAGE BUFFER READ
Syntax:
RBD
Access level: USER
Tx State:
Enabled
This command returns the number of bytes in the message and the message as it was sent to the
GOES transmitter.
Random Message Length = 119 bytes
Random Message is:
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
tttttttttttttttttttttttttttttttttttttttttttttt
OK