Settings
Below is a detailed description of the "Settings" menu item for the "Charging set-
tings" menu item discussed above. Navigation is performed as described in the
"Configuration mode" section.
A list appears with the following selection options:
The individual selection options are explained in greater detail below:
Electrolyte circulation ("Air pump") - for 3 kW (C1) devices only:
More information on the electrolyte
circulation can be found under
"Electrolyte circulation 3 kW (C1)" in
the "Options" chapter.
The electrolyte circulation cycle is controlled by the battery charger's control
system. A number of selection options are available for this purpose.
The following settings are available for electrolyte circulation:
-
Off:
-
Electrolyte circulation switched off
-
Continuous operation ("continuous"):
-
Electrolyte circulation permanently on
-
Program 1 to 5:
-
Default electrolyte circulation programs and their relevant parameters
can be found in the table under "Settings" in the "Display" chapter.
-
Automatic:
-
Automatic adjustment of electrolyte circulation flow rate based on the
set battery parameters
-
"User" - "On"/"Off":
-
Individual setting of the electrolyte circulation
-
The settings for "On" and "Off" determine the pulse/pause ratio of the
air flow intervals
Default electrolyte circulation programs and their relevant parameters can be
found in the table below:
Program
ON 1
OFF 1
Repeat
ON 2
OFF 2
1
30 min
25 min
1 x
5 min
25 min
2
3 min
10 min
4 x
3 min
20 min
3
3 min
12 min
1 x
3 min
12 min
4
5 min
10 min
3 x
5 min
20 min