Day Setting 1-5:
The day settings allow up to five dif-
ferent charging start time profiles to
be defined with the following set-
tings:
-
Symbol for characteristic 1:
Time window in which charging is
to be started using characteristic 1
(e.g. 0:00-6:00)
-
Stop:
Time window in which charging
must not take place (e.g.
6:00-20:00)
-
Symbol for characteristic 2:
Time window in which charging is
to be started using characteristic 2
(e.g. 20:00-24:00)
Please note:
Ongoing charging operations are not affected by the set time windows.
If in the example above a battery is connected at 5:45, the charge end time is
governed by the requirements of the battery and is not interrupted by the end
time specified for the set time window (6:00 in the example).
If the battery is connected during the "stop" time window, charging is started
automatically during the next time window.
If charging is started manually during the "stop" time window, charging will al-
ways take place using characteristic 1.
Additional settings:
-
Change the allocated characterist-
ic:
characteristics symbol
-
Remove the selected characterist-
ic:
"remove"
Week Setting:
-
Three different week settings can
be defined.
A previously created day setting can be
assigned to any day of the week.