Adjusting the Gas Nozzle Clamping Device
Adjusting the gas
nozzle clamping
device
CAUTION!
An incorrectly set gas nozzle clamping device may damage the cleaning device
and the welding torch.
▶
When using gas nozzles with an outside diameter of 25 mm (0.98 inches), the gas
nozzle clamping device must not be adjusted - the gas nozzle clamping device has
already been set for the use of gas nozzles with an outside diameter of 25 mm (0.98
inches) as part of the factory calibration.
▶
When using gas nozzles with an outside diameter larger/smaller than 25 mm (0.98
inches), the gas nozzle clamping device must be adjusted before it is started for the
first time and after every device replacement.
(1)
(3)
(2)
(4)
NOTE!
Set the clamping device so that no
reaction forces can be transmitted to
the robot.
Only clamp gas nozzles on a cylindrical
surface.
1
Loosen the Allen screws on guide
bolts (1) and (2)
2
Move the welding torch to the cleaning
position
-
centric to the cleaning motor
3
Use the adjusting screw (3) to position
the clamping device (4) so that the
clamping device is positioned against
the gas nozzle
4
Tighten the Allen screws on guide bolts (1) and (2)
NOTE!
Only clamp the gas nozzle in a central position over the cleaning motor.
34
Summary of Contents for Robacta Reamer X-Line J
Page 2: ......
Page 11: ...General 11 ...
Page 12: ...12 ...
Page 15: ...Warning before the device switches on automatically 15 EN US ...
Page 18: ...18 ...
Page 19: ...Operating controls connections and mechanical components 19 ...
Page 20: ...20 ...
Page 25: ...Installation and Startup 25 ...
Page 26: ...26 ...
Page 53: ...Service maintenance and disposal 53 ...
Page 54: ...54 ...
Page 58: ...Disposal Materials should be disposed of according to valid national and regional rules 58 ...
Page 59: ...Troubleshooting 59 ...
Page 60: ...60 ...
Page 65: ...Technical data 65 ...
Page 66: ...66 ...
Page 68: ...68 ...
Page 69: ...Appendix 69 ...
Page 73: ...73 ...
Page 74: ...74 ...
Page 75: ...75 ...