5.4
ELECTRICAL CONNECTION
2
1
4
3
The machine is supplied with a cable
(1)
without a plug and already
connected to the terminal board on the electric panel.
DANGER
IT IS MANDATORY TO CONNECT A PLUG TO THE SUPPLIED CABLE ;
IT IS NOT PERMITTED TO CONNECT THE CABLE INSIDE AN
ELECTRICAL PANEL.
DANGER
THE ELECTRICIAN MUST CORRECTLY FIT AN APPROPRIATE PLUG
ACCORDING TO THE CURRENT REGULATIONS IN THE COUNTRY OF
USE.
DANGER
THE ELECTRICAL POWER SYSTEM CONNECTED TO THIS PRODUCT
MUST BE SET UP IN CONFORMITY WITH THE SAFETY STANDARDS
CURRENTLY IN FORCE, EQUIPPED WITH A DIFFERENTIAL SWITCH
AND AN EARTH CIRCUIT. THE VOLTAGE AND FREQUENCY MUST BE
COMPATIBLE WITH THE REQUISITES GIVEN ON THE IDENTIFICATION
PLATE.
The differential must be type B or F and a maximum of 300
mA and not less than 100 mA.
The plug must be wired as shown in the following colour scheme:
Brown: Phase - Blue: Neutral - Yellow - Green: Earth
Connect the earth cable
(3)
with 10mm² section (not supplied) in the
relevant hole
(4)
in the machine base.
DANGER
ANY FAULTS OR ANOMALIES IN THE EARTH CIRCUIT CONNECTED TO
THE MACHINE CAN, IN THE EVENT OF BREAKDOWN, LEAD TO THE
OPERATOR SUFFERING ELECTRIC SHOCK WITH THE CONSEQUENT
RISK OF DEATH OR SERIOUS INJURY TO THEIR HEALTH.
Picture 58
Summary of Contents for FS380
Page 2: ...Rev 2 01 03 2021 SUMMARY 2 ...
Page 6: ...IV Rev 2 01 03 2021 Use and Maintenance Manual TURNTABLE MAST IV ...
Page 8: ...2 Rev 2 01 03 2021 Use and Maintenance Manual TURNTABLE MAST 2 ...
Page 33: ...Fromm 27 MACHINE DESCRIPTION 27 ...
Page 54: ...48 Rev 2 01 03 2021 Use and Maintenance Manual TURNTABLE MAST 48 ...
Page 57: ...Fromm 51 MACHINE DESCRIPTION 51 OPTIONAL OPTIONAL H M E I B A D Ø N 0 L G F Picture 31 ...
Page 65: ...Fromm 59 TRANSPORT HANDLING STORAGE 59 ...
Page 99: ......
Page 100: ...Fromm Holding AG Hinterbergstrasse 26 6312 Steinhausen Switzerland ...