ELECTRICAL TESTS
Page 61
Service Manual Deli Multisserie form 9123667 rev. 20220317
• In case there fuses were blown before, first check
the wiring to and from the transformer and blo-
wers. Also check discoloration of the transformer.
• Select X6 and push OK
In case the fuses F1 or F2 still blow, switch off the
mains supply and proceed as follows.
1. Disconnect the 2 capacitors and unscrew them from
the blower suction channel. (Metric 13)
2. Remove the grommet and take out the hose.
3. Unscrew 2 nuts (metric 10) and 2 bolts (with nut,
metric 8) and remove the blower suction channel
4. Connect the 2 capacitors.
5. Disconnect both blowers. Therefore disconnect wire
60 from terminal X3.
6. Switch ON the mains supply and activate output X6.
7. In case the fuses still blow, the transformer is broken
or the wires to and from the transformer maybe
shorted.
8. In case the fuses stay, then check the voltages accor-
ding the previous page, in the high speed table.
9. In case these voltage differ, the transformer is bro-
ken.
10. In case the voltages are OK, one or both blowers
have a short circuit, or the wires to the blowers
may be shorted.
11. Switch OFF the mains supply (power) and discon-
nect the wires 61 and 68 from the screw terminals
of the lower blower and insulate them.
12. Re-connect wire 60 to terminal X3 on the pcb.
13. Switch on the power and activate output X6.
14. In case the upper blower is running normally, the
lower blower is broken.
15. Check the running blower by measuring the cur-
rent. This is 0,85A
16. In case the blower is not running, the capacitor
might be broken. The current will than be 1,7A.
16. Switch off the power and exchange the broken
blower.
17. Re-connect all wires on the blowers, activate
output X6 and check the transformer voltages and
blower current.
Note that in case an insulation tester was available, a
broken blower would have been detected already
with the resistance values. See page 48.
1
1
22
33
55
77
88
44
33
X7 X5 X3
X6 X4
X15 X14
X6
X5
X4
X3
6µF
6µF
M2
M3
C2
C3
59
96
66
97
67
68
60
61
transformer
fan speed
upper
fan
fan
lower
X7
108
0V
X14
37
40
X15
N
L
60 61
240V
230V
220V
208V
165V
145V
200V
Violet
Blue
Green
Yellow
Orange
Red
Brown
Black
1 2 3 4 5 6 7 8 9
67
97 59
66 96
Summary of Contents for Deli Multisserie
Page 2: ...TABLE OF CONTENTS Page 2 Service Manual Deli Multisserie form 9123667 rev 20220317 EMPTY PAGE...
Page 69: ...ELECTRICAL TESTS Page 69 Service Manual Deli Multisserie form 9123667 rev 20220317...
Page 85: ...TROUBLE SHOOTING Page 85 Service Manual Deli Multisserie form 9123667 rev 20220317 EMPTY PAGE...
Page 132: ...Page 132 Service Manual Deli Multisserie form 9123667 rev 20220317...