Rev 3 Service Manual MCC Hot / Cold 2021
Page 59
Lights & digital inputs ("Lit" folder)
dOd
Enable utility switch-off on activation of door switch
0
num
dad
Activation delay for digital input
0
min
dCO
Compressor deactivation delay after door opened
0
min
dCd
Fans activation delay after door closed
10
secs
Pressure switch ("Pre" folder)
Pen
Number of errors allowed for general pressure switch input
5
num
PEI
Minimum/maximum pressure switch error count interval
1
min
Pet
Delay in activating compressor after pressure switch deactivation
0
min
Deep cooling ("dEC" folder)
dCA
Enable deep cooling
0
num
dCS
Deep cooling setpoint
-1
°C
tdC
Deep cooling duration
0
min
dcc
Defrost delay after deep cooling
0
min
Sid
Deep cooling start threshold
12
°C
toS
Over-threshold time for deep cooling start
5
min
Energy saving ("EnS" folder)
Est
Energy Saving mode
0
num
ESA
AUX output status in energy saving mode
0
num
ESF
Night mode activation for fans
y
flag
Cdt
Door close time
60
min*10
ESo
Cumulative door open time for disabling Energy Saving mode
0
num
OSP
Offset on setpoint
0,5
°C
OdF
Intervention differential correction
4
°C
dnt
Duration of night mode
10
hours
dFt
Duration of fast cooling mode
1
hours
SPn
Night mode setpoint
1
°C
dFn
Night mode offset
2
°C
SPF
Fast cooling setpoint
-1
°C
dFF
Fast cooling offset
0,1
°C
ESP
Virtual door regulator's sensitivity
0
num
dOt
Maximum Time Door Open with virtual door switch
0
secs
Communication ("Add" folder)
PtS
Communication protocol selection
t
flag
dEA
Device address
0
num
FAA
Family address
0
num
Pty
Modbus parity bit setting
n
num
StP
Modbus stop bit setting
1b
flag
Display ("dIS" folder)
LOC
LOCk Setpoint change shutdown
n
flag
PS1
Password 1
0
num
PS2
Password 2
0
num
ndt
Display with decimal point
y
num
CA1
Calibration 1 (Pb1)
4,8
°C
CA2
Calibration 2 (Pb2)
0
°C
CA3
Calibration 3 (Pb3)
0
°C
ddL
Display mode during defrost
2
num
Ldd
Timeout value for display unlick
15
min
9.2
Parameter MCC Cold Settings (Full Serve)
Summary of Contents for Cold MCC
Page 20: ...Page 20 Rev 3 Service Manual MCC Hot Cold 2021 Circuit diagram evaporator tray...
Page 21: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 21 Wiring diagram evaporator tray...
Page 29: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 29 5 1 MCC 90 Drop in Dimensions Self Serve...
Page 39: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 39 6 0 Installation Front door section...
Page 77: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 77 Page intentionally left blank...
Page 103: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 103 Page intentionally left blank...
Page 139: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 139 17 0 Electrical schematics MCC Cold Self Serve...
Page 140: ...Page 140 Rev 3 Service Manual MCC Hot Cold 2021...
Page 141: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 141 17 1 Electrical wiring MCC Cold Self Serve N L...
Page 142: ...Page 142 Rev 3 Service Manual MCC Hot Cold 2021...
Page 143: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 143 17 2 Circuit Diagram MCC Hot Full Serve...
Page 144: ...Page 144 Rev 3 Service Manual MCC Hot Cold 2021 17 3 Electrical wiring MCC Hot Full Serve...
Page 145: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 145...
Page 146: ...Page 146 Rev 3 Service Manual MCC Hot Cold 2021...