Parameter MCC Cold Settings (Full Serve)
MCC Cold FS
Eliwell EWPlus 974 EO
9124651
Rev. A
Parameter
Description
Value
Unit
SEt
Temperature Setpoint
1,0
°C
diF
Compressor relay activation differential
1
°C
HSE
Maximum value that can be assigned to the Setpoint
5
°C
LSE
Minimum value that can be assigned to the Setpoint
-1
°C
dty
Type of defrost (0 = electrical, 1 = reverse cycle, 2 = "Free")
0
num
dit
Interval between the start of two consecutive defrost cycles
6
hours
dEt
Defrost timeout; determines the maximum defrost duration
30
min
dSt
Defrost end temperature (determiend by evaporator probe)
4
°C
FSt
Fan stop temperature
50
°C
Fdt
Fan activation delay after a defrost cycle
0
min
dt
Coil drainage time
0
min
dFd
Allows to select the evaporator probes exclusion during defrost
n
flag
HAL
Maximum temperature alarm
10
°C
LAL
Minimum temperatre alarm
-30
°C
tAO
Temperature alarm signal delay time
30
min
dCS
Deep cooling cycle setpoint
-1
°C
tdC
Deep cooling cycle duration
0
min
OSP
Offset on setpoint
0,5
°C
OdF
Intervention differential correction
4
°C
dnt
Duration of night mode
10
hours
DFt
Duration of fast cooling mode
1
hours
SPn
Night mode setpoint
1
°C
dFn
Night mode offset
2
°C
SPF
Fast cooling setpoint
-1
°C
dFF
Fast cooling offset
0,1
°C
LOC
LOCk Setpoint change shutdown
n
flag
PS1
Password 1
0
num
CA1
Calibration 1 (Pb1)
4,8
°C
CA2
Calibration 2 (Pb2)
0
°C
CA3
Calibration 3 (Pb3)
0
°C
ddt
Display mode during defrost
2
num
Ldd
Timeout value for display unlick
30
min
H42
Evaporator probe present
y
flag
rEL
firwarme rELease
tAb
tAble of parameters
Parameter
Description
Value
Unit
SEt
Temperature Setpoint
1
°C
Compressor ("CP" folder)
diF
Compressor relay activation differential
1
°C
HSE
Maximum value that can be assigned to the Setpoint
5
°C
LSE
Minimum value that can be assigned to the Setpoint
-8
°C
Ont
Controller on time for faulty probe
0
min
Oft
Controller off time for faulty probe
1
min
Table of "user" menu paramters
Table of "installer" menu parameters
Summary of Contents for Cold MCC
Page 20: ...Page 20 Rev 3 Service Manual MCC Hot Cold 2021 Circuit diagram evaporator tray...
Page 21: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 21 Wiring diagram evaporator tray...
Page 29: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 29 5 1 MCC 90 Drop in Dimensions Self Serve...
Page 39: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 39 6 0 Installation Front door section...
Page 77: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 77 Page intentionally left blank...
Page 103: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 103 Page intentionally left blank...
Page 139: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 139 17 0 Electrical schematics MCC Cold Self Serve...
Page 140: ...Page 140 Rev 3 Service Manual MCC Hot Cold 2021...
Page 141: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 141 17 1 Electrical wiring MCC Cold Self Serve N L...
Page 142: ...Page 142 Rev 3 Service Manual MCC Hot Cold 2021...
Page 143: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 143 17 2 Circuit Diagram MCC Hot Full Serve...
Page 144: ...Page 144 Rev 3 Service Manual MCC Hot Cold 2021 17 3 Electrical wiring MCC Hot Full Serve...
Page 145: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 145...
Page 146: ...Page 146 Rev 3 Service Manual MCC Hot Cold 2021...