Page 106 

Rev 3 Service Manual MCC Hot / Cold  2021

13.0

 Exploded view MCC Hot 

(Self Serve)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22 23

24

25

26

27

28

29

30

31

32

33

Complete assy 

           250

Summary of Contents for Cold MCC

Page 1: ...onvenience counters MCC configurations and is not intended to be all encompassing The individual specifications may differ Procedures for which you do not have the necessary tools instruments or skill...

Page 2: ...ion maintenance or repair activities even if not explicitly described in this manual As a result of constant commitment to improvement it may happen that your unit deviates in detail from what is desc...

Page 3: ...CC Hot Settings Self Serve 62 10 0 Trouble Shooting 65 11 0 Replacement and Adjustments 78 12 0 Technical Specifications MCC Cold Self Serve 92 13 0 Exploded view MCC Hot Self Serve 104 14 0 Exploded...

Page 4: ...oltage Frequency Power consumption 1 3 Pictograms and symbols In this manual the following pictograms and symbols are used WARNING symbols WARNING WARNING Possible physical injury or serious Risk of F...

Page 5: ...and carefully follow all guidelines and instructions Never change the order of the steps to be performed The pictograms labels instructions and warning signs attached to the unit are part of the safet...

Page 6: ...unit in a well ventilated area with sufficient floor space refer to the data sheet for minimum space requirement Do not install the unit in basements in area s with open flames or high surface temper...

Page 7: ...ort The electrical schematics of the unit are included at the end of this manual In case of malfunctions which are not fixable by you you can contact Fri Jado Make sure you have the following data ava...

Page 8: ...t always be kept in place For MCC Cold SS Price rail is integrated part of air guidance inside the unit Removing the price rail will result in a bad functioning MCC Self serve models have an additiona...

Page 9: ...over models between 40 C and 85 C 104 F and 185 F One LED module per level provides lighting of the products The LED lighting and the heating are switched on and off separately In the future Lightning...

Page 10: ...nstalled operated and serviced in a safe manner the instructions provided by the manufacturer should be adhered to at all times The cabinets can also be supplied with or without under frame to be inst...

Page 11: ...be done either by hand or automatically For the automatic filling system an additional electrical box is implemented which controls the filling process Hand filling system Automatic filling system Ho...

Page 12: ...l and contact the transporter as soon as possible but at the latest within fifteen working days after receiving the goods 3 1 Unpacking the unit The MCC is placed inside a crate during transport take...

Page 13: ...nting of optional front doors There are 2 different heights of plastic washers to align the height of the front doors Position the doors with the handles to the outside and with the warning sticker ab...

Page 14: ...the door in a tilted position during this action Press the hinge pin at the upper side downwards Turn the door in a vertical position so the upper hinge pin will align with the upper hole Release the...

Page 15: ...unit s legs Refer to next page MCC cold Please take notice of label with minimum space required Be sure that the personnel have sufficient room to work with the unit Keep a distance of at least 150 mm...

Page 16: ...al price rails for Hot self serve models can be mounted using the front screws underneath each of the Hot SS shelves Do not loosen this screws entirely Price rails for serve over models can be mounted...

Page 17: ...of horizontal levels Refer to user manual 4 5 Solid back option On request the unit can be ordered having a solid back in stead of sliding doors 4 6 First use Before starting to use the unit clean the...

Page 18: ...nth by attaching it to both rear Adjustable legs using its two clamps Insert the pegs of both side plinths into the slots of the rear plinth Secure the side plinths by inserting the pegs into the slot...

Page 19: ...ication 1 Turn of unit and pull power plug from wall outlet 2 Open back panel of unit refer 11 16 3 Extend drain of unit using the delivered drain pipe Cut pipe on required length depending on measure...

Page 20: ...Page 20 Rev 3 Service Manual MCC Hot Cold 2021 Circuit diagram evaporator tray...

Page 21: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 21 Wiring diagram evaporator tray...

Page 22: ...ure controller Let the unit cool for approx 30 minutes Loading the unit Only load products of which the temperature is maximum 4 C 39 2 F The maximum loading height is 50mm 2 inch below the bottom of...

Page 23: ...384461 MCC 90 Shelf insert 400x475 mm Middle Shelf 9384470 MCC 90 Shelf insert 400x550 mm Bottom Shelf 9384471 MCC 90 Shelf insert 550x410 mm Top Shelf 9384537 MCC120 Shelf insert 550x475 mm Middle Sh...

Page 24: ...389813 9389813 Price rail set MCC 150 9389814 9389814 9389814 Evaporation tray 9389820 9389820 9389820 Bumper MCC 90 9380207 9380207 9380207 Bumper MCC 120 9380205 9380205 9380205 Bumper MCC 150 93802...

Page 25: ...Cold 2021 Page 25 5 0 MCC Drop in Doc nr 9124590 Rev 0 Registration form MCC Drop in Unpack instruction The MCC Drop in will be delivered packed in a crate Start unpacking by removing top cover For i...

Page 26: ...9124590 Rev 0 Registration form MCC Drop in Unpack instruction Remove short sides first Left and Right by unscrewing them Next remove front and back panel they are also screwed onto the support beams...

Page 27: ...ve corner pieces EPS foam Unit is placed on a metal sub frame for transport purposes Frame is kept together with metal strip at the front and the back Keep strip in place during placing process Keep w...

Page 28: ...documents and glass shelfs from unit After placing cabinet in final position remove tie wraps which hold the shelf holders Make sure the shelf holders are placed in the required sleeve for the wanted...

Page 29: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 29 5 1 MCC 90 Drop in Dimensions Self Serve...

Page 30: ...00 475 x 1400 Dimensions top shelf mm n a 410 x 800 410 x 1100 410 x 1400 Shelf display area m2 n a 1 18 1 62 2 07 Usable display volume l n a 258 355 452 Drain diameter mm n a 32 Minimum room floor a...

Page 31: ...ote Airflow inside the cabinet is crucial Air intake and Air outlet are not allowed to interfere A physical barrier must be placed in between the two air flows Air inlet and air outlet surfaces must c...

Page 32: ...es the back panel of the counter can be removed Provide enough space to place the counter with a stacker Maintain the dimensions and minimum height as indicated in the installation manual also applies...

Page 33: ...till easily accessible for service after installation by means of a removable hatch Provide enough space to place the counter with a stacker Maintain the dimensions and minimum requirements as indicat...

Page 34: ...x D x H mm 720 x 870 x 1460 1020 x 870 x 1460 1320 x 870 x 1460 Nr of presentation levels 3 n a Dimensions bottom shelf mm 550 x 500 550 x 800 550 x 1100 n a Dimensions middle shelf mm 475 x 500 475 x...

Page 35: ...allation instruction 3 Step 1 Position the cabinet above the cut out in the counter top with a forklift and support it using the wooden beams supplied with the unit Step 2 Lift the cabinet from below...

Page 36: ...4589 Rev 0 Registration form MCC Drop in installation instruction 4 Step 3 Apply sealant or a thin flexible foam seal around the cut out in the countertop Carefully lower the cabinet into the counter...

Page 37: ...e and screws up to 1 meter from the original position Step 6 Install a partition panel to prevent recirculation of hot condenser air refrigerated models only Step 7 Install all remaining trim panels M...

Page 38: ...v 3 Service Manual MCC Hot Cold 2021 Make sure after build in the cool engine is still accessible Keep in mind the complete engine is extendable at the back side of the unit for maintenance and servic...

Page 39: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 39 6 0 Installation Front door section...

Page 40: ...ont underframe panel two screws one on each bottom corner Drop In Raise the unit at least 30cm from tabletop level in order to access the screws for the child guard Be careful to support the unit such...

Page 41: ...ylon washer with collar 1 Glass Nylon washer with collar 2 Step 9 Place hinge on glass door One on the bottom one on top Hight adjustment washer 3701241 and 3701242 For placement washers wait till ste...

Page 42: ...uck Remove back cover s left and right sliding door stopper Both fixed with three screws Step 15 Place new longer top column cover two screws Re mount side glass holder the first screw Mount second sc...

Page 43: ...se same screws to mount Place nylon bearing in profile packet in bag with hinge Step 18 Place bumper rubber in bottom profile two Step 19 Place top profile set step 3 in top column cover Step 20 Place...

Page 44: ...in height yet so they can scratch the bottom plate Always place hight adjustment nylon washer first before placing the bottom hinge pin in its bearing Step 22 Adjust glass door height by adjusting pos...

Page 45: ...ont underframe panel two screws one on each bottom corner Drop In Raise the unit at least 30cm from tabletop level in order to access the screws for the child guard Be careful to support the unit such...

Page 46: ...lay a protection or a locked start up Off otherwise Defrost LED Permanently on defrost active Flashing manual or D I activation Off otherwise Alarm LED Permanently on alarm active Flashing alarm ackno...

Page 47: ...cool for at least 30 minutes Loading the unit Only load products of which the temperature is maximum 4 C 39 2 F The maximum loading height is 50mm 2 inch below the bottom of the shelf air guide above...

Page 48: ...To unlock the keypad press and hold for at least 3 seconds until the label UnL appears 2 Press and release SET to access the Machine status menu 3 Scroll through the folders with and until you find t...

Page 49: ...eck all function are working correctly 8 0 1 Control Panel On Off Switches hot unit Heating Lighting 8 0 2 Factory settings The unit is set at 65 C 149 F intake air temperature If required this temper...

Page 50: ...ain switch is displayed Switch OFF main switch r12 0 for changing the pre installed application Press UP DOWN to scroll through the parameter list Configure the o61 parameter to select a pre installed...

Page 51: ...he lighting with appropriate switch next to controller 8 2 1 Loading the unit Only place products that have a core temperature of at least 85 C 185 F or above Only with packaged hot products in bags o...

Page 52: ...nce to keep a daily cleaning pattern from first use onwards Maintenance schedule for users For detailed cleaning instructions refer to User manual chapter 5 Examples Cleaning possibility the top glass...

Page 53: ...rost cycle 0 min dt Coil drainage time 0 min dFd Allows to select the evaporator probes exclusion during defrost n flag HAL Maximum temperature alarm 10 C LAL Minimum temperatre alarm 30 C tAO Tempera...

Page 54: ...erval 1 num dOH Defrost start delay time after request 0 min dEt Defrost timeout determines the maximum defrost duration 30 min dSt Defrost end temperature determiend by evaporator probe 4 C dPO Deter...

Page 55: ...0 min dCO Compressor deactivation delay after door opened 0 min dCd Fans activation delay after door closed 10 secs Pressure switch Pre folder Pen Number of errors allowed for general pressure switch...

Page 56: ...alibration 2 Pb2 0 C CA3 Calibration 3 Pb3 0 C ddL Display mode during defrost 2 num Ldd Timeout value for display unlick 15 min dro Select C or F 0 num ddd Selection of type of value to be displayed...

Page 57: ...emperature alarm signal delay time 30 min dCS Deep cooling cycle setpoint 1 C tdC Deep cooling cycle duration 0 min OSP Offset on setpoint 0 5 C OdF Intervention differential correction 4 C dnt Durati...

Page 58: ...ntial 1 C Fdt Fan activation delay after a defrost cycle 0 min dt Coil drainage time 0 min dFd Allows to select the evaporator probes exclusion during defrost n flag FCO Evaporator fans operating mode...

Page 59: ...gy saving mode 0 num ESF Night mode activation for fans y flag Cdt Door close time 60 min 10 ESo Cumulative door open time for disabling Energy Saving mode 0 num OSP Offset on setpoint 0 5 C OdF Inter...

Page 60: ...ut 2 0 num H21 Configurability of digital output 1 1 num H22 Configurability of digital output 2 3 num H23 Configurability of digital output 3 5 num H25 Enable Disable buzzer 0 num H32 Configurability...

Page 61: ...out voltage 0 V A75 Maximum voltage 270 V d01 Defrost method no no defrost nAt natural no d02 Defrost stop temperature 6 C d03 Defrost Interval 8 hr d04 Max defrost time 30 min d05 Defrost delay at po...

Page 62: ...nable no A73 Minimum cut in voltage 0 V A74 Minimum cut out voltage 0 V A75 Maximum voltage 270 V d01 Defrost method no no defrost nAt natural no d02 Defrost stop temperature 6 C d03 Defrost Interval...

Page 63: ...ne R290 Exclusively electrical devices may be used inside the unit that are certified by the applicable ATEX directive The cooling circuit and refrigeration system of the unit must not be damaged This...

Page 64: ...r by unscrewing two closing screws depending on the version Screws Keep condenser free from dirt and dust clean regularly For cleaning use a long haired soft brush and a vacuum cleaner Be aware not to...

Page 65: ...certified and qualified persons in a well ventilated environment 10 0 2 Replace the mains cord WARNING Hazardous electrical voltage If the mains cord is damaged it must be replaced by a fully certifi...

Page 66: ...27 28 50 10 17 96 68 20 12 09 77 25 10 00 Temperature Resistance F C 5 Ohms 4 20 951 14 10 877 32 0 807 50 10 740 68 20 677 77 25 990 10 0 5 Heating element testing Full Serve units Resistance 1 Remov...

Page 67: ...rm the Alarm icon located in the upper left part will light up To display the active alarm you have to press the set key and look for the AL folder In the following table you will be able to see all t...

Page 68: ...save the changes Installer parameters When accessed the display will show the first folder e g CP Press and to scroll through the folders on the current level Select the desired folder using set Pres...

Page 69: ...temperature or the temperature relative to the Setpoint 67 0 320 C F 50 0 50 0 50 0 20 0 50 0 Fdt Fan activation delay after a defrost cycle 0 250 min 0 0 0 0 0 dt Coil drainage time 0 250 min 0 0 0 0...

Page 70: ...mpressor stops a defrost cycle is performed according to parameter dtY 3 temperature 0 1 2 3 num 1 1 1 1 1 0 1 1 1 0 1 1 dOH Defroststartdelaytimeafterrequest 0 59 min 0 0 0 0 0 0 0 0 0 0 0 0 dEt Defr...

Page 71: ...int CPS 0 255 min 0 0 0 0 0 0 0 0 0 0 0 0 LIGHTS DIGITALINPUTS Lit folder dOd Enable utility switch off on activation of door switch 0 disabled 1 disables fans 2 disables the compressor 3 disables fan...

Page 72: ...Ffordisplayingthetemperaturereadbyprobes 0 C 1 F NOTE switching between C and F or vice versa DOES NOT modify the SEt diF values etc e g Setpoint 10 C becomes 10 F 0 1 num 0 0 0 0 0 0 0 0 0 0 0 0 ddd...

Page 73: ...cordedbyprobePb2 Recordingof labelAd2 infolderAL Alarmiconpermanentlyon waitforthenextdefrostcycleforautomatic return Ad3 endof defrost cycleduetotimeout activation of the defrost for temperature inde...

Page 74: ...ring connection 5 Air flow not functioning Unit does not reach desired temperature 1 Heating element malfunction HOT unit only 2 Cooling unit malfunction COLD unit only 3 Strong air current along unit...

Page 75: ...k Resistance refer 6 4 Replace element Check wiring Check power on fans per shelf Replace Air box Power Supply Cooling engine COLD unit Cooling system does not initiate compressor doesn t run Wiring c...

Page 76: ...Loose sensor Broken Sensor Loose sensor Clean condensor with long haired soft brush Replace sensor Check sensor wiring Replace sensor Check sensor wiring Air out sensor Cold Unit Ice on evaporator The...

Page 77: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 77 Page intentionally left blank...

Page 78: ...are of the weight of the glass 2 Remove the air guide for the hot version or the air box for the cold version by simply lifting them out HOT COLD 3 Loosen the adjusting screws which secure the glass w...

Page 79: ...tirety past the top guide CAUTION Once past the top guide the glass pane might fall if not properly held Hence do not leave it standing upright without being supported by both guide rails or holding i...

Page 80: ...rsions please select appropriate type In order to replace the sliding doors take following step 1 Remove Sliding door stopper three screws Left and right side 2 Remove rail cover loosen mounting screw...

Page 81: ...type Recognizable Two screws on top of rail cover Top back side two left and two right In order to replace the sliding doors take following step 1 Remove Sliding door stopper three screws Left and rig...

Page 82: ...each 2 Lift bottom shelf at the front It is turnable 3 Sensor is located at the back 4 Sensor is screwed from the outside in 5 Remove glass pane from lowest shelf see 11 10 6 Remove fan box see 11 9 7...

Page 83: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 83 11 6 Sensor Replacement Cold Unit Defrost sensor Under construction Air out sensor Under construction...

Page 84: ...unting screws 3x of child glass Screwed from underneath 3 Place new child glass 4 Mount in reverse order Mounting screws 11 8 MCC Air guide replacement 1 Air guide replacement 2 For replacement open t...

Page 85: ...move glass pane clamp 4 or more bolts depending on unit length 3 Remove Glass pane refer 11 10 4 Remove air box 1 connector two screws 5 Replace in reverse order Note If replacement has to take place...

Page 86: ...ir outlet cover by removing the screws depending on length three or more screws 2 Remove glass mounting profile by removing the screws depending on length three or more screws 3 Lift out glass pane st...

Page 87: ...some versions you also need to loosen the screws on the side of the under storage compartment After loosening the screws you can remove the panel by pulling it slightly down and then turning it towar...

Page 88: ...screw top 5 Disconnect connector in Column before you do so make a note of the placing of the red and black cable in the connector 6 Take LED light out of LED light holder and place new LED 7 Connect...

Page 89: ...ment NEVER make a connection underneath the heating element Connect the wires in the column using a wago connector like the one on this picture Take care of connecting Red to Red Blue to Blue and Yell...

Page 90: ...2 2 Remove Top glass See 11 1 3 Take out Air guide see 11 8 4 Remove Air box by unscrewing the mounting screws at the back 5 Remove colomn covers left and right back by unscrewing the top and bottom s...

Page 91: ...3 Replace in reverse order Back panel 1 Remove back panel by removing the holding screws left and right bottom corner Bottom view 2 Pull panel slightly towards you and down to remove 3 Replace in rev...

Page 92: ...F max 25 C 77 F min 17 C 62 2 F max 25 C 77 F min 17 C 62 2 F max 25 C 77 F Relative Humidity max 60 max 60 max 60 Noise Level at workspace 70 dB A 70 dB A 70 dB A Voltage 1N 230V 1N 230V 1N 230V Fre...

Page 93: ...ve Humidity max 60 max 60 max 60 Noise Level at workspace 70 dB A 70 dB A 70 dB A Voltage 1N 230V 1N 230V 1N 230V Frequency 50 Hz 50 Hz 50 Hz Max nominal Current 3 9 A 4 2 A 5 2 A Plug 2 pole earthed...

Page 94: ...1420 mm Weight Net approx 152 kg 335 lbs 179 kg 395 lbs 206 kg 454 lbs Ambient Temperature min 20 C 68 F max 30 C 86 F min 20 C 68 F max 30 C 86 F min 20 C 68 F max 30 C 86 F Relative Humidity max 60...

Page 95: ...86 F min 20 C 68 F max 30 C 86 F Relative Humidity max 60 max 60 max 60 Noise Level at workspace 70 dB A 70 dB A 70 dB A Voltage 1N 230V 1N 230V 3N 400 230V Frequency 50 60 Hz 50 60Hz 50 60 Hz Max no...

Page 96: ...475 410 209 250 296 840 1420 480 100 750 600 585 475 410 209 250 296 840 1420 480 100 585 475 410 209 250 296 840 1420 MCC 120 Cold MCC 150 Cold 1200 mm 1500 mm 750 mm 750 mm 1420 mm 1420 mm 1320 mm...

Page 97: ...00 750 600 585 475 410 209 250 296 840 1420 480 100 750 600 585 475 410 209 250 296 840 1420 480 100 1N 230V 1N 230V 50 Hz 50 Hz 0 56 kW 0 67 kW R290 3 R290 3 MCC 90 Cold drop in version MCC 120 Cold...

Page 98: ...nical information please visit w MCC 1200 1500 750 600 100 750 600 585 475 410 209 250 296 840 1420 480 100 MCC COLD 012020 www frijado com endment without prior notice tion please visit www frijado c...

Page 99: ...5 410 243 250 290 840 1420 480 100 750 600 550 475 410 243 250 290 840 1420 480 100 550 475 410 243 250 90 840 20 MCC 90 Hot MCC 120 Hot 900 mm 1200 mm 750 mm 750 mm 1420 mm 1420 mm 1053 mm 1053 mm 1N...

Page 100: ...al information please 600 900 1200 750 600 100 750 600 550 475 410 243 250 290 840 1420 480 100 750 600 550 475 410 243 250 290 840 1420 480 100 50 Hz 50 Hz 3 02 kW 4 19 kW MCC 60 Hot drop in version...

Page 101: ...al information please v 900 1200 750 600 100 750 600 550 475 410 243 250 290 840 1420 480 100 MCC HOT 012020 www frijado com MCC 90 Hot drop in version MCC 120 Hot drop in version amendment without pr...

Page 102: ...Rev 3 Service Manual MCC Hot Cold 2021 MCC placed on wheels will alway need a floor seal as seen on picture in order to prevent warm outlet air being sucked in at the air inlet condensor side back sid...

Page 103: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 103 Page intentionally left blank...

Page 104: ...Page 104 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Complete assy 250...

Page 105: ...lf MCC 60 Rear cover Shelf MCC 90 Rear cover Shelf MCC 120 9384303 9384235 9384304 15 Fan Box Middle MCC 60 Fan Box Middle MCC 90 Fan Box Middle MCC 120 9380072s 9380058s 9380074s See remark serial nu...

Page 106: ...Page 106 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Complete assy 250...

Page 107: ...S 60 middle 230V Assy shelf MCC Hot SS 60 large 230V Assy shelf MCC Hot SS 90 small 230V Assy shelf MCC Hot SS 90 middle 230V Assy shelf MCC Hot SS 90 Large 230V Assy shelf MCC Hot SS 120 small 230V A...

Page 108: ...Page 108 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 64 65 66 67 68 69 70 71 72 73 75 76 77 78 79 80 81 82 72 300...

Page 109: ...ding door 120 Right V1 9380226s 9380216s 9380220s 9380210s 9380222s 9380212s 1 1 1 1 1 1 70 Assy Glass sliding door 60 Left Assy Glass sliding door 90 Left Assy Glass sliding door 120 Left 9380217s 93...

Page 110: ...Page 110 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 34 36 37 38 39 40 41 42 43 44 45 50 52 46 53 54 55 56 57 58 59 60 53 61 62 55...

Page 111: ...9384091 50 Led driver EDXe 160 12 054 30007730 52 Box electronics 9384094 53 Strain relief Nut for cable gland 9222076 9222077 54 End Clamp Clip fix 35 5 PHX 9191222 55 Terminal PT 4 GN YE Terminal P...

Page 112: ...Page 112 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Self Serve 159 160 161 162 163 164 165 166 167 168 169 170 171 173 171 174 175 176 177 178 179 180 181 183 81 182 300...

Page 113: ...r panel 9384021 1 169 Side panel MCC 9384005 2 see 181 170 Glass Top Shelf 410 mm MCC 90 Glass Top Shelf 410 mm MCC 120 Glass Top Shelf 410mm MCC 150 9382052s 9382056s 9382109s 1 1 1 171 Assy price ra...

Page 114: ...Page 114 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Self Serve 131 132 133 137 138 139 140 141 143 144 145 146 147 148 149 150 151 150 152 153 156 157 158...

Page 115: ...EO 9381018 1 138 Sticker Black Elect Sign triangle 3500105 1 139 Data plate 9110810 1 140 Sensor NTC 9381017 141 Sensor NTC 9381017 143 Cover electronics box 9384095 1 144 Din Rail1 9293057 145 End C...

Page 116: ...Page 116 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Self Serve 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 126 125 127 128 129 130...

Page 117: ...S 50 30005928 120 Connection tube 9383015 121 Clamp 31 37 2650216 122 Pipe support Armafix 2650252 123 Fluid dryer Danfoss 7650204 1 124 Connection tube 9383014 125 126 Compressor 9381003 1 127 Valve...

Page 118: ...Page 118 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Full Serve 83 84 85 86 87 88 89 90 91 92 93 95 94 96 97 98 99 100 101 102 103 104 105 106 107 108 109...

Page 119: ...9382083 9382119 91 Insulation front 9382077 1 92 Inner shell MCC 90 Inner shell MCC 120 Inner shell MCC 150 9384096 9384142 9384219 93 94 Product plateau support MCC 90 Product plateau support MCC 120...

Page 120: ...Page 120 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Full Serve 159 160 161 162 163 165 166 167 168 169 170 173 176 177 178 179 180 181 183 81 182 164 175 300...

Page 121: ...e 181 170 Glass Top Shelf 410 mm MCC 90 Glass Top Shelf 410 mm MCC 120 Glass Top Shelf 410mm MCC 150 9382052 9382056 9382109 1 1 1 171 Assy price rail glass shelf MCC 90 Assy price rail glass shelf MC...

Page 122: ...Page 122 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Hot Full Serve 64 65 66 69 70 71 72 73 74 75 76 77 80 81 82 72 78 67 68 85 83 84 300...

Page 123: ...ing door 90 Left Assy Glass sliding door 120 Left 9380217s 9380211s 9380213s 1 1 1 71 Back panel MCC 60 Back panel MCC 90 Back panel MCC 120 9384006 9384007 9384008 1 1 1 72 Side glass topside bracket...

Page 124: ...ge 124 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Hot Full Serve 83 85 86 87 89 90 91 92 93 95 94 96 97 98 99 102 106 107 108 109 L 200 201 202 203 204 205 206 207 208 209 210 211 2...

Page 125: ...ulation bottom MCC 120 9382076 9382083 9382119 91 Insulation front 9382077 1 92 Inner shell MCC 60 Inner shell MCC 90 Inner shell MCC 120 9384096 9384142 9384219 102 Rosette type 240 1 1 4 9381001 106...

Page 126: ...Page 126 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Hot Full Serve 34 36 37 38 40 41 42 43 44 45 50 52 46 53 54 55 56 57 58 59 60 53 61 62 64 65 66 67 68 69 70 71...

Page 127: ...5 Led 3000k 12V 400mm MCC 60 Led 3000k 12V 700mm MCC90 Led 3000k 12V 1000mm MCC 120 9382075 9382067 9382068 44 Led Armature support bracket 9384091 50 Led driver EDXe 160 12 054 30007730 52 Box electr...

Page 128: ...1 24 Glass shelf middle MCC 60 9382036s 2 1 24 Glass shelf middle MCC 90 9382140s 2 1 24 Glass shelf middle MCC 120 9382080s 2 1 28 Heating element 475x540 750W MCC 60 9382090 2 1 28 Heating element 7...

Page 129: ...0 Left V0 V1 9380215s 73 Side glass MCC 9382030s 2 2 79 Childguard assy MCC60 9380017s 2 1 79 Childguard assy MCC90 9380018s 2 1 79 Childguard assy MCC120 9380019s 2 1 175 Childguard assy MCC 150 9380...

Page 130: ...p Shelf 410mm MCC 150 9382109s 3 1 171 Assy price rail glass shelf MCC 60 9380146s 3 3 171 Assy price rail glass shelf MCC 90 9380052s 3 3 171 Assy price rail glass shelf MCC 120 9380073s 3 3 Assy pri...

Page 131: ...8x13 ZP Self drilling and tapping 866 4287620 Screw 4 2x12 NP self tapping 868 4285078 Nut 1 4 bsw ZP 871 9191049 Set screw M5x5 black 872 4285010 Nut M3 ZP with lockwasher Pos Part nr Description 87...

Page 132: ...M4x20 thread rolling 951 8071043 Nut M4 serrated ZP 952 6962187 953 0197807 Screw M4x30 slotted ZP 954 4285084 Screw 4 8x19 ZP Self drilling and tapping 955 9008217 Blind rivet 4x8 6 956 9174680 Wash...

Page 133: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 133 16 0 Electrical schematic MCC Hot Self Serve One Phase Schematics for Serial number starting from serial number...

Page 134: ...Page 134 Rev 3 Service Manual MCC Hot Cold 2021 16 1 Electrical wiring MCC Hot Self Serve One Phase A1 A2 1L1 3L2 5L3 7L4 2T1 4T2 6T3 8T4 N L N L GN 2A 1A 5B 4B 5B 4B 2A 1A...

Page 135: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 135 16 1 Electrical schematic MCC Hot Self Serve One phase and time relais Schematics for Serial number before serial number...

Page 136: ...136 Rev 3 Service Manual MCC Hot Cold 2021 N L N L GN 5 6 2A 1A 5B 4B 5B 4B 2A 1A Tijd relais instellen 2m tijdspanne 12 5 tijd BE modus 16 1 Electrical wiring MCC Hot Self Serve One phase and time re...

Page 137: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 137 16 2 Electrical schematic MCC Hot Self Serve Three phase...

Page 138: ...Page 138 Rev 3 Service Manual MCC Hot Cold 2021 16 2 Electrical wiring MCC Hot Self Serve Three phase...

Page 139: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 139 17 0 Electrical schematics MCC Cold Self Serve...

Page 140: ...Page 140 Rev 3 Service Manual MCC Hot Cold 2021...

Page 141: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 141 17 1 Electrical wiring MCC Cold Self Serve N L...

Page 142: ...Page 142 Rev 3 Service Manual MCC Hot Cold 2021...

Page 143: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 143 17 2 Circuit Diagram MCC Hot Full Serve...

Page 144: ...Page 144 Rev 3 Service Manual MCC Hot Cold 2021 17 3 Electrical wiring MCC Hot Full Serve...

Page 145: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 145...

Page 146: ...Page 146 Rev 3 Service Manual MCC Hot Cold 2021...

Page 147: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 147 Fri Jado B V Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel 31 0 76 50 85 400...

Reviews: