M O N I T O R I N G T R A F F I C
User Guide
7-15
Lastly the user can determine whether or not the alert should be generated once or always. When
always is selected, the syslog message is sent one time, and a counter is incremented for every
interval that goes over the threshold within the alert-record table.
Policy Configurator
After an alert is configured the user can now tie the alert to a specific policy. In the policy
command the following configuration option has been added.
Example CLI Command
set policy from untrust to trust any any any permit [alertname] [conn-rate
aggr-bw bw_conn]
[NOTE]
alert-name options are conn-rate aggr-bw bw_conn. For each option you use, you must list them
in this order.
[NOTE]
The log option in the alert configuration works based on how logging is configured by the user.