background image

 WARNING -  RISK OF ELECTRICAL SHOCK

Have an electrician provide electrical power to the motor.

Motor  must  be  grounded  and  terminal  cover  in  place  to

reduce electrical shock hazard.

Keep motor operating area as dry as possible.

A  ground  fault  interrupter  (GFI)  protected  circuit  is

recommended for use with any electrical device operating

near water.

Always disconnect power before servicing.

Not investigated for use in swimming pool areas.

SAFETY  WARNINGS

BEFORE  OPERATING  OR  

INSTALLING  THIS  PUMP,  READ  

THIS  MANUAL  AND  FOLLOW  

ALL  SAFETY  RULES  AND  

OPERATING  INSTRUCTIONS. 

 WARNING - ELECTRICAL PRECAUTIONS

All  wiring,  electrical  connections,  and  system  grounding  must 

comply with the National Electrical Code (NEC) and with any local 

codes and ordinances.  Employ a licensed electrician.  For non-

thermally protected motors use with approved motor control that 

matches motor input in full load amperes with overload element(s) 

selected or adjusted in accordance with control instructions.

 CAUTION

DO NOT OPERATE THIS PUMP DRY!

Review instructions before operating.

 SAFETY 

 

CAREFULLY  READ  THESE  SAFETY

MESSAGES  IN  THIS  MANUAL  AND  ON  PUMP.

APPLICATION

This pump is suitable for installations where the vertical distance 

from the pump to the water level does not exceed 25 ft. 

In all installations, friction losses in the suction pipe must be 

taken into consideration.

PERFORMANCE

INSTALLATION

be increased by one size.  The suction pipe must always slope 

upwards from the water source to the pump to avoid air pockets in 

the line.  In cases where the pump has to be reprimed often and it 

is not necessary that a lot of water be delivered, it is advisable to 

use a 90° or 45° elbow on the suction line.  This enables the pump 

to prime sooner and also prevents kinking of the hose.  In cases 

where a maximum volume of water is required over a pro-  

longed period of time, the suction line should be led almost hori-

zontally to the pump.  Non-toxic thread compound should be used 

on all pipe joints and connections should be thoroughly tightened.  

A strainer should be connected to the bottom end of the suction 

pipe and it should be well submerged at all times.

     FOR DUAL VOLTAGE MOTORS

Voltage change instructions are located on motor label or on 

wiring access cover.

HP

Flow in GPM 

at total head (ft.)

Flow in L/min. 

at total head (meters)

50

75

100 125 150

20

30

40

50

3

110

92

71

40

--

371 276

110

--

5

--

141 121

98

66

560 466 348 148

OWNER’S MANUAL

Self-Priming Sprinkler Pump

PUMP LOCATION: 

 The pump should be installed in a clean, dry 

and ventilated location which provides adequate drainage and 

room for servicing and protection from freezing temperatures.  It 

should be bolted down evenly on a good foundation, preferably 

concrete, to prevent the development of unnecessary stress.  

Locating the pump as close as possible to the source of water 

supply reduces the friction losses in the suction pipe and provides 

for maximum capacities.

SUCTION PIPE: 

 It is recommended that only new clean pipe 

or hose be used and the size be the same as that of the pump 

suction tapping.  If the pump is installed any appreciable distance 

away from the source of water supply, the suction pipe should

Summary of Contents for Turf Boss

Page 1: ...to avoid air pockets in the line In cases where the pump has to be reprimed often and it is not necessary that a lot of water be delivered it is advisable to use a 90 or 45 elbow on the suction line...

Page 2: ...leeder in place of the priming plug or an air bleed line with a gate valve connected to the discharge line It will then be possible for the liquid to remain in the discharge pipe and allow the pump to...

Page 3: ...sure pump casing and suction line are full of water See priming instructions Speed too low WARNING ELECTRICAL PRECAUTIONS All wiring electrical connections and system grounding must comply with the N...

Page 4: ...was designed and manufactured 2 Product not installed in accordance with applicable codes ordinances and good trade practices 3 Product connected to voltage other than indicated on nameplate 4 Pump us...

Page 5: ...m ment aux instructions qui l accompagnent tous les cas il faut tenir compte des pertes de charge dans la conduite d aspiration le diam tre de la conduite d aspiration devrait tre plus grand La condui...

Page 6: ...OMPE Pour amorcer la pompe il faut enlever le bouchon d amor age se trouvant sur le dessus du bo tier remplir le bo tier d eau et remettre le bouchon en place La dur e d amor age est fonction de la di...

Page 7: ...e lisse en c ramique plac e vers le haut Figure 2 Bouchon de vidange Bouchon d amor age Refoulement ENTRETIEN c Remonter la plaque d tanch it ou l adaptateur sur le moteur d Mouiller la bague en caout...

Page 8: ...pas une garantie et ne peut tre consid r e par l utilisateur comme faisant partie du contrat de vente La seule obligation du vendeur ou de l Entreprise et le seul recours de l acheteur est le remplace...

Page 9: ...TENCIA PELIGRO DE DESCARGA EL CTRICA CABLEADO Aseg resequeelvoltajeylafrecuenciadelsuminis tro el ctrico concuerde con los indicados en la placa de marca del motor Si tiene dudas comun quese con la co...

Page 10: ...tra vez mientras que la v lvula de chequeo incorporada funcione CUIDADO NO haga funcionar la bomba antes de llenar el cuerpo de la misma con agua ya que puede da ar el sello CARGADO BAJO PRESI N Vea l...

Page 11: ...su caja en la plancha selladora o adaptador con el lado liso de cer mica hacia arriba c Ensamble al motor la plancha selladora o el adaptador d Moje el anillo de goma del conjunto del sello con jab n...

Page 12: ...to por parte del vendedor la Compa a los representantes o cualquier otra parte no constituye garant a alguna no debe ser considerada como tal por el usuario y no forma parte del contrato de venta La n...

Reviews: