24
English
After clicking on “Factory Default” a new screen opens (Fig. 21) where you can select whether to restore the
factory settings for the selected module. In the dropdown menu, select the module to reset and select “Factory
default” to complete resetting the default for the module.
8.5 FIRMWARE UPGRADE
From the OPERATIONS -> UPDATE FIRMWARE -> UPDATE FIRMWARE menu, you can check the firmware
release version installed and then update the system if required.
To update the system, check there is the correct update package available in a PC folder or in the USB drive,
then select the update package and press on BROWSE and then UPDATE MODULES. Wait until the end of the
updating operation.
After updating, check the result from the menu OPERATIONS -> UPDATE FIRMWARE -> UPDATE RESULT menu.
8.6 RESTART MODULES
From the OPERATIONS -> RESTART menu the system can be restarted.
9. PROGRAMMING INSTRUCTIONS
INTRODUCTION: before programming the 3DG-4ASI-4T the following general instructions should be observed.
Decide whether you want to use the ALL PID OUT function or to program every single program (PID) that will
have to be available in the output.
With the ALL PID function, the transport stream received from the specified input is rebroadcast at the output
with no further processing.
Therefore the output channels need no management, and all the contents, including non-standard or erroneous
in the original transport stream, will be rebroadcast without change, ensuring compatibility with other more
“rigid” decoders in managing the input data. However, at the same time, the programs or priorities cannot be
managed in the case of overflow issues.
If the output available bitrate is insufficient, due to the lack of priority management, EACH program in the output
transport could lose packages, meaning only artefacts are viewed on the TV. Therefore, the ALL PID mode should
only be used when the output band is the same or higher than the input band.
If the programs are managed singularly for every PID, it is advisable to carefully follow the following indications so