DDM Configuration
134
The last threshold-
violation doesn‘t exist.
Ethernet 1/0/22 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-
violation doesn‘t exist.
Step2: Enable the transceiver monitoring of ethernet 21.
Switch(config)#interface ethernet 1/0/21
Switch(config-if-ethernet1/0/21)#transceiver-monitoring enable
Step3: Show the transceiver monitoring of the fiber module. In the following configuration,
ethernet 21 enabled the transceiver monitoring, the last threshold-violation time is Jan 02
11:00:50 2011, the detailed DDM information exceeding the threshold is also shown.
Switch(config-if-ethernet1/0/21)#quit
Switch(config)#show transceiver threshold-violation interface ethernet 1/0/21-22
Ethernet 1/0/21 transceiver threshold-violation information:
Transceiver monitor is enabled. Monitor interval is set to 30 minutes.
The current time is Jan 02 12:30:50 2011.
The last threshold-violation time is Jan 02 11:00:50 2011.
Brief alarm information:
RX loss of signal
RX power low
Detail diagnostic and threshold information:
Diagnostic Threshold
Realtime Value High Alarm Low Alarm High Warn Low Warn
------------ ----------- ----------- ------------ ---------
Temperature
(
℃
)
33 70 0 70 0
Voltage
(
V
)
7.31 10.00 0.00 5.00 0.00
Bias current
(
mA
)
3.11 10.30 0.00 5.00 0.00
RX Power
(
dBM
)
-30.54(A-) 9.00 -25.00(-34) 9.00 -25.00
TX Power
(
dBM
)
-1.01 9.00 -12.05 9.00 -10.00
Ethernet 1/0/22 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-
violation doesn‘t exist.