EFM OAM Configuration
111
instance
Fig 12-3 Typical
OAM application topology
Configuration procedure: (Omitting SNMP and Log configuration in the following)
Configuration on CE:
CE(config)#interface ethernet1/0/1
CE (config-if-ethernet1/0/1)#ethernet-oam mode passive
CE (config-if-ethernet1/0/1)#ethernet-oam
CE (config-if-ethernet1/0/1)#ethernet-oam remote-loopback supported
Other parameters use the default configuration.
Configuration on PE:
PE(config)#interface ethernet 1/0/1
PE (config-if-ethernet1/0/1)#ethernet-oam
Other parameters use the default configuration.
Execute the following command when using remote loopback.
PE(config-if-ethernet1/0/1)#ethernet-oam remote-loopback
Execute the following command to make one of OAM peers exiting OAM loopback after
complete detection.
PE(config-if-ethernet1/0/1)# no ethernet-oam remote-loopback
Execute the following command without supporting remote loopback.
CE(config-if-ethernet1/0/1)#no ethernet-oam remote-loopback supported
12.4
EFM OAM Troubleshooting
When using EFM OAM, it occurs the problem, please check whether the problem is
resulted by the following reasons:
Check whether OAM entities of two peers of link in passive mode. If so, EFM OAM
connection can not be established between two OAM entities.
Ensuring SNMP configuration is correct, or else errored event can not be reported to
network management system.
Link does not normally communicate in OAM loopback mode, it should cancel remote
loopback in time after detect the link performance.
CE
PE
802.1ah OAMPDU
Ethernet
1/0/1
Ethernet
1/0/1