28
2) Re insert the code with the required functionning way:
0 E
start of programming
12345 E
supercode
1 E
identification
5 E
monostable mode, timed 5”
55127 E
new code
After this operation the code 55127 will activate the relay 1 in
monostable mode for 5”.
6) Panic function
When the operator needs to send an alarm signal without being
seen to do so, he can activate the panic function.
The panic code, which consists of a single digit, must be keyed in
after one of the relay codes and this gives activation of both the
selected relay and the timed panic output (approx. 5”).
(AC for FT3188 or AL for FT3328)
Procedure for programming the panic function:
1) Key in “
0
” “
E
” (start of programming control).
2) Make sure the LED is on.
3) Key in the programming
supercode
(see point 1),
followed by “
E
”.
4) Key in “
4
” (selection of panic function), followed by “
E
”.
5) Key in the
panic code
(1 digit), followed by “
E
”.
6) Check that the LED is turned off.
E.g.:
to programme panic code of 3, key in the following:
0 E
start of programmation
12345 E
supercode
4 E
panic function
3 E
panic code
This means that when the relay code followed by the panic code is
keyed in, both the output relay and panic relay are activated
(timing=approx. 5”): 71032 3 E.
• The panic code must be keyed in after the relay code and
before the final E.
• If the panic code is activated, the relay code must not have
more than 7 figures.
• The relay codes must nor end with the digit chosen for the
activation of the panic function.
• The panic output has an open collector (500 mA max).
7) Programming of accepted number of errors
This enables the number of code-forming errors which can be keyed
in before the block function intervenes to be programmed.
For example, if a value of 3 is fixed, at the third incorrect attempt to
form a code the key will temporarily lock for approximately one
minute. It is also possible to transmit an alarm signal (
AL
output)
after accepted incorrect attempts, if this has been provided when
programming.
If you need to transmit the alarm signal, “
1
” will be keyed in during
programming otherwise “
0
” will be set in programm (see procedure
below).
An attempt to insert an incorrect code is considered keying in a
number not previously coded followed by “
E
”.
Procedure for programming the number of accept errors
1) Key in “
0
” “
E
” (start of programming control).
2) Make sure the LED is on.
3) Key in the
supercode
(see point 1), followed by “
E
”.
4) Key in “
5
” (selection of
“block error”
function), followed by “
E
”.
5) Key in the number of accepted errors (1-9), without “
E
”.
6) Key in: “
1
” “
E
” if you wish an alarm signal to be transmitted when
locking occurs. “
0
” “
E
” if no alarm signal is to be transmitted.
7) Check that the LED is turned off.
E.g.:
to programme locking after 3 errors without an alarm signal, key in
the following:
0 E
start of programming
12345 E
supercode
5 E
“error” function
3
number of incorrect attempts accepted
0 E
no alarm signal
Enabling of “key”
push-button
By short-circuiting terminals CK1 and CK2, e.g. by means
of a timer, it is possible to activate relay 1 without forming
the relay code, simply by pressing the “key” push-button
on the keypad
.
Reset input (FT3188 only)
Connecting this input to the negative (-), operation of the keypad will
block completely and all outputs will be deactivated (relays
and alarms).
Remote input for enabling of
push-button
(for FT3328 only)
By connecting the contact
RK
to ground, Relay 1 is activated for 5
sec. The maximum distance for this contact is 20 metres .
Terminal boards description:
~- ~+
power supply 12V DC/AC
CK1
contact enabling the “key” push-button
CK2
contact enabling the “key” push-button (for FT3188 only)
CK2
contact enabling the “key” push-button/negative
(for FT3328 only)
+OUT
positive not adjusted
AC-
panic output , 500 mA max (FT3188 only)
AL-
alarm output (and panic for FT3328) (500 mA max)
L2 L1
free (FT3188 only)
NO/2
relay 2
C/2
relay 2
NC/2
relay 2
NO/1
relay 1
C/1
relay 1
NC/1
relay 1
PGM
programming input
RST
remote reset input (FT3188 only)
GND -
negative (FT3188 only)
RK
remote input for enabling of key p. button (FT3328 only)
Summary of Contents for DIGI-2
Page 1: ...D I G I 2 S Y S T E M T E C H N I C A L M A N U A L ...
Page 17: ...TM 15 TM U P yellow green A L T O A L T O U P MIC U P 8 9 10 11 12 13 ...
Page 18: ...TM 16 U P UP U P UP ALTO UP U P U P 1 2 14 15 16 SOLUTION A SOLUTION B ...
Page 36: ...TM 34 2 3 1 6 5 4 5 Installation of monitor on desk support FT5712 ...
Page 57: ...TM 55 TM ...
Page 59: ...TM 57 TM ...
Page 61: ...TM 59 TM ...
Page 62: ...TM 60 Connection of a MAX 9 riser branches for each Mixer power supply FT4896 Diagram 8 ...
Page 65: ...TM 63 TM ...
Page 80: ...TECHNICAL MANUAL 1 a edition 01 2008 Cod 22591745 ...