TM
19
TM
5) ACCESS CONTROL
This function allows activation of the door-opening relay in the porter module (Contact
SE / SE) by entering a previously stored password code (see paragraph CARRYING
OUT DOOR OPENING BY ENTERING THE PASSWORD CODE).
*
N.B: The values in
brackets indicate the
min and max limits
of the parameter
(ref. table page 21).
If the entry has been made
correctly.
If the parameter does
not come within the
foreseen limits.
ON DISPLAY
DESCRIPTION
OPERATION
Select the SETTINGS /
SYSTEM PARAM. /
ADDRESS RS485
menu by means of
the key.
To cancel an operation
or to exit the menu
press the
X
key.
Enter the desired value
of the parameter.
Press the
key
to confirm the value
of the parameter.
ADD.RS485 ( 1 -255 )
*
VALUE: _ _ _
PARAMETER
CHANGED
Or:
WRONG
ENTRY
INITIAL CONDITION
Module supplied
LANGUAGE (1-10):
VALUE:_ _ _
4C) SETTING THE LANGUAGE
The value of this parameter is used to set the language for the messages. If it is the first
time module FT3070/A has been turned on, you must proceed as described below:
*
N.B: The values in
brackets indicate the
min and max limits
of the parameter
(ref. table page 21).
The DEFAULT item sets
the messages in ITALIAN.
The next time the module
is turned on, selection
of the language is
requested again.
If the entry has been made
correctly.
ON DISPLAY
DESCRIPTION
OPERATION
LANGUAGE (1-10):
*
VALUE: 2 _ _
PARAMETER
CHANGED
Enter the value of the
parameter. EXAMPLE:
if you want to set the
ENGLISH language.
To cancel the operation,
press
X
.
Press the
key
to confirm the value
of the parameter.
To modify the value of the parameter, if the value set is not DEFAULT:
INITIAL CONDITION
Access to the configuration
stage has been carried out
(see point 4A).
The module is in the
program-ming stage.
Menu scrolling takes
place automatically
every 2 seconds.
MAIN
SETTINGS
*
N.B: The values in
brackets indicate the
min and max limits
of the parameter
(ref. table page 21).
If the entry has been made
correctly.
ON DISPLAY
DESCRIPTION
OPERATION
LANGUAGE (1-10)
VALUE:2 _ _
LANGUAGE (1-10):
*
VALUE: 2 _ _
PARAMETER
CHANGED
Select the menu
SETTINGS / LANGUAGE.
To select, press
.
To exit, press
X
.
Enter the value
of the parameter.
Press the
key
to confirm the value
of the parameter.
5A) ENTERING A PASSWORD CODE
INITIAL CONDITION
Access to the configuration
stage has been carried out
(see point 4A).
The module is in the
program-ming stage.
Menu scrolling takes
place automatically
every 2 seconds.
MAIN
SETTINGS
The password code can have
a maximum of 6 figures.
If the code entered does
not exist in the memory.
It is possible to enter up to
300 password codes.
If the code entered already
exists in the memory.
ON DISPLAY
DESCRIPTION
OPERATION
PASSWORD
VALUE: _ _ _ _ _ _
PASSWORD
VALUE:_ _ _ 100
STORING
IN PROGRESS…….
Or:
ALREADY
EXISTING
Select the ACCESS
CONTR. / PASSWORD /
ENTER menu by means
of the
key.
To exit press
X
.
Enter the password code
desired.
EXAMPLE:
100
Press the key
to
confirm the entry.
5B) ELIMINATION OF A PASSWORD CODE
INITIAL CONDITION
Access to the configuration
stage has been carried out
(see point 4A).
The module is in the
program-ming stage.
Menu scrolling takes
place automatically
every 2 seconds.
MAIN
SETTINGS
The password code can have
a maximum of 6 figures.
If the code entered does
not exist in the memory.
It is possible to enter up to
300 password codes.
If the code entered already
exists in the memory.
ON DISPLAY
DESCRIPTION
OPERATION
PASSWORD
VALUE: _ _ _ _ _ _
PASSWORD
VALUE:_ _ _ 100
STORING
IN PROGRESS…….
Or:
ALREADY
EXISTING
Select the
ACCESS CONTROL /
PASSWORD / DELETE
menu by means
of the
key.
To exit press
X
.
Enter the password code
desired.
EXAMPLE:
100
Press the key
to
confirm the entry.
Summary of Contents for DIGI-2
Page 1: ...D I G I 2 S Y S T E M T E C H N I C A L M A N U A L ...
Page 17: ...TM 15 TM U P yellow green A L T O A L T O U P MIC U P 8 9 10 11 12 13 ...
Page 18: ...TM 16 U P UP U P UP ALTO UP U P U P 1 2 14 15 16 SOLUTION A SOLUTION B ...
Page 36: ...TM 34 2 3 1 6 5 4 5 Installation of monitor on desk support FT5712 ...
Page 57: ...TM 55 TM ...
Page 59: ...TM 57 TM ...
Page 61: ...TM 59 TM ...
Page 62: ...TM 60 Connection of a MAX 9 riser branches for each Mixer power supply FT4896 Diagram 8 ...
Page 65: ...TM 63 TM ...
Page 80: ...TECHNICAL MANUAL 1 a edition 01 2008 Cod 22591745 ...