![fortessa DIGI-2 Technical Manual Download Page 22](http://html.mh-extra.com/html/fortessa/digi-2/digi-2_technical-manual_2321466022.webp)
TM
20
5C) ELIMINATION OF A PASSWORD CODE
INITIAL CONDITION
Access to the configuration
stage has been carried out
(see point 4A).
The module is in the
program-ming stage.
Menu scrolling takes
place automatically
every 2 seconds.
MAIN
SETTINGS
Pressing the
X
key allows
the operation to be
cancelled.
ON DISPLAY
DESCRIPTION
OPERATION
DELETE
ALL PASSWORDS ?
DELETING
Select the
ACCESS CONTROL /
PASSWORD / DELETE ALL
menu by means of the
key.
To exit press
X
.
To confirm
press the
key.
The module is in the
program-ming stage.
Menu scrolling takes
place automatically
every 2 seconds.
5D) CHANGING THE SUPERCODE
INITIAL CONDITION
Access to the
configuration stage
has been carried out.
ACCESS CONTROL
SUPERCODE
The supercode must have
6 figures.
The new supercode value
is 222222.
ON DISPLAY
DESCRIPTION
OPERATION
SUPERCODE
VALUE: _ _ _ _ _ _
SUPERCODE
VALUE: 222222
PARAMETER
CHANGED
Select the
ACCESS CONTROL /
SUPERCODE /
MODIFICATION menu by
means of the
key.
To exit press
X
.
Enter the new supercode
value.
EXAMPLE: 222222
Press the
key
to confirm the entry.
5E) CHANGING THE SUPERCODE TO THE DEFAULT VALUE
INITIAL CONDITION
Access to the configuration
stage has been carried out
(see point 4A).
The module is in the
program-ming stage.
Menu scrolling takes place
automatically
every 2 seconds.
MAIN
SETTINGS
The supercode has been
modified to the default
value (111111).
ON DISPLAY
DESCRIPTION
OPERATION
PARAMETER
CHANGED
Select the RESET
SUPERCODE menu by
means of the
key.
To exit press
X
.
5F) DISPLAYING THE NUMBER OF PASSWORDS ENTERED
AND THE SOFTWARE VERSION INSTALLED IN MODULE FT3070/A
INITIAL CONDITION
Access to the configuration
stage has been carried out
(see point 4A).
The module is in the
program-ming stage.
Menu scrolling takes
place automatically
every 2 seconds.
MAIN
SETTINGS
The software version
installed in module
FT3070/A is displayed
on the first line.
The number of
password codes
entered is displayed
on the second line.
ON DISPLAY
DESCRIPTION
OPERATION
REV 1.0
PASSWORDS:100
Select the INFO
menu by means
of the
key.
5G) CARRYING OUT A DOOR OPENING OPERATION BY ENTERING THE PASSWORD
CODE
INITIAL CONDITION
Module FT3070/A supplied
in stand-by.
ENTER
TENANT CODE
To cancel the operation,
press the
X
key.
ON DISPLAY
DESCRIPTION
OPERATION
PASSWORD: _ _ _ _ _ _
CONFIRM WITH
PASSWORD: _ _ _ 100
CONFIRM WITH
Press the
key.
Enter the password code
EXAMPLE:
100
If the password code exists
in the memory. The SE / SE
contact of the porter module
will be activated.
If the password code does
not exist in the memory.
PASSWORD
CONFIRMED
Or:
ENTER
TENANT CODE
Press the
key.
6B) INSERTING A LIST ( DOWNLOAD )
By means of the software FT1249/A it is possible to enter the list with the
Indirect code
and
Code
fields for the INDIRECT CODE operating mode inside module FT3070/A.
The FT3070/A must be set in indirect code call mode (see paragraph 4B-4).
6) INDIRECT CODE
6A) MULTIDOWNLOAD
It is possible to create an RS485 system with digital call modules FT3070/A to upload or
download an user name list on any of the modules on this system, using a pc upgraded
with software FT1249/A version 2.2 or later.
Each module must have different ID CODE (see paragraph 4B-5).
INITIAL CONDITION
Module supplied in
stand-by.
ENTER
TENANT CODE
Summary of Contents for DIGI-2
Page 1: ...D I G I 2 S Y S T E M T E C H N I C A L M A N U A L ...
Page 17: ...TM 15 TM U P yellow green A L T O A L T O U P MIC U P 8 9 10 11 12 13 ...
Page 18: ...TM 16 U P UP U P UP ALTO UP U P U P 1 2 14 15 16 SOLUTION A SOLUTION B ...
Page 36: ...TM 34 2 3 1 6 5 4 5 Installation of monitor on desk support FT5712 ...
Page 57: ...TM 55 TM ...
Page 59: ...TM 57 TM ...
Page 61: ...TM 59 TM ...
Page 62: ...TM 60 Connection of a MAX 9 riser branches for each Mixer power supply FT4896 Diagram 8 ...
Page 65: ...TM 63 TM ...
Page 80: ...TECHNICAL MANUAL 1 a edition 01 2008 Cod 22591745 ...