184
26. Connecting to Routers
The switcher can also connect to a router other than FOR-A MFR-5000 series routers.
The router control is based on the HARRIS Pass-Through protocol.
To connect a router other than an MFR-5000 series router, two RS-422 interfaces, one
for controlling the router and the other for receiving TSL protocol, are required.
26-1. Assigning a Router Channel to an RS-422 port
(1) Display the [SETUP-SYSTEM-RS-422] menu.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>
RS-422
>TIME >INIT >REBOOT
(2) Turn F1 to select a port for connecting a router.
(3) Select ROUTER under
FUNC
.
(4) Set
BAUD
(baudrate) to 57600 and
PARITY
to NONE. (These settings may vary depeding
on routers. Refer to your router's User Manual.)
SYSTEM :SELECT :FUNC :BAUD :PARITY : 1/1
RS-422 : =
PORT1
:=
ROUTER
: =57600: =NONE :
(5) Reboot the switcher after settings are complete. (See section 22-1. "Rebooting System".)
26-2. Router Control
The router can be controlled in the same way as described for MFR-5000 series routers. See
section 25-2. "Router Control."
26-3. Linking Titles and Tallies in the System via TSL Protocol
HVS-350HS
Router
RS-422
RS-422
2
Multiviewer
(UMD)
RS-422
3
RS-422
TSLRx
(Receive)
See 24-3-1.
TSL
(Send)
See 23-3-1.
RS-422
4
RS-422
1
RS-422
Router control
See 23-2.
Video titles
Video titles
& Tallies
Summary of Contents for HVS-350HS
Page 224: ......
Page 227: ...Appendix 3 1 HVS 30OU for HVS 350HS Operation Unit 1st Edition APPENDIX 3 ...
Page 258: ......