4
Rear Panel
No.
Name
Description
Refer to
1
SDI INPUT
Used to input HD/SD SDI video signal. 8 inputs (BNC)
2 SDI
OUTPUT Used to output HD/SD SDI video signal. 8 outputs (M/E
PGM, P/P PGM and 6 auxiliary outputs) (BNC)
3
EDITOR
Used for editor connection. (9-pin D-sub, female)
4 LAN
Used for 100BASE-TX/1000BASE-T Ethernet connection.
(RJ-45)
5
GPI IN
Used for GPI input. (15-pin D-sub, female)
6 GPI/TALLY
OUT
Used for GPI output and Tally output. (25-pin D-sub,
female)
7 TO
OU
Used for HVS-35OU/35ROU connection via Arcnet. It can
also be used to connect the Hanabi AUX control boxes.
(BNC)
One of two terminals is used for loop-through connection. It
must be 75-ohm terminated if not looped-through.
8 REF
IN
Used to input a genlock signal; tri-level sync or black burst.
(BNC)
The center terminal is used for loopthrough connection. It
must be 75-ohm terminated if not looped-through.
9
REF OUT
Used to output a reference signal
10 RS-422
4 ports (9-pin D-sub, female)
Used to connect external devices such as Hanabi tally
units, HVS-30RU, VTR/VDCP devices, routers and audio
mixers.
11
Option Slots
Used to install optional input/output expansion cards.
12 AC
IN1
Power 1 connection with ground terminal
(AC100V-240V 50/60 Hz)
13 AC
IN2
Power 2 connection with ground terminal
(AC100V-240V 50/60 Hz)
RATING LABEL
D
B
E
C
A
OPTION SLOT
F
I/O
4
3
2
1
SDI IN PUT
6
7
8
5
AU X
2
RS-422
1
PG M
PGM
M/E
P/P
4
1
2
3
5
6
CP U/GE NLOCK
TO OU
GENLOCK
R EF IN
RE F OUT
GPI IN
ED ITOR
GPI/TALLY OU T
4
RS-422
3
2
1
AC10 0V - 24 0V 50 /60 Hz IN