17
(3) Fault message contact (2x)
An error status can be reported via these open/closed contacts. The fault contact relay (2 x UM)
should be operated with a maximum of 50 V and 500 mA.
One of the two 3-pin Phoenix connectors can be used as a link!
(4) FOHHN-NET Input (2x)
The
DLI-130/230 AES
can be connected to the
FOHHN-NET
remote control network via these 3-pin
Phoenix connectors
One of the two 3-pin Phoenix connectors can be used as a link!
(5) Switching contact
This 3-pin Phoenix connector serves as a switching contact for changing presets. This can be
configured in
FOHHN AUDIO SOFT
(see Chapter 3.4.3 “Switching contacts“)
.
(6) Mains connection
Mains connection is via a 2-pin WAGO (grounding screwed). The switching power supply (with Power
Factor Correction) allows a supply voltage of 100 V – 240 V AC / 4 A / 50/60 Hz.
WAGO terminal for mains connection with two pins (1) and (3) and grounding screw (2)