24
19.1
Language
•
This function allows you to choose from the following languages available (Pt – Portuguese; Nl – Dutch; Gr
– Greek; It – Italian; En – English; Fr – French; Es – Spanish; De – German).
19.2
Eco mode
•
If the unit is equipped with a thermostat that operates exclusively based on temperature, the "eco mode"
can be enabled to reduce the fuel consumption. In this mode, the unit operates at a user-defined set
point temperature.
•
The unit always runs at maximum operating power until it reaches a temperature of 1ºC above the set
point temperature. Upon reaching this temperature, the unit starts operating at minimum operating
power for a pre-set period of time (20 minutes). After this time has elapsed, the unit turns off. It remains
off until it reaches 2º C below the set point temperature specified, for a pre-set period of time (20
minutes). Then, the unit turns back on, and a new operation cycle begins.
•
This mode is only available in automatic mode.
19.3
Lighting
•
This menu allows you to determine whether the display should be lit or not.
19.4
Tones
•
Allows you to select the sound of the touch keys on the display when pressed.
19.5
Temperature unit (°C / °F)
•
You can select if you want the temperature measured in degrees Celsius (°C ) or Fahrenheit (°F).
19.6
Pellet recipe
•
The “receita de pellets” (Pellet recipe) menu allows the user to adjust the pellet dosage that goes into the
unit's burner. Press "set" to display the "Actuações transitórias" (Temporary activations) menu.
Summary of Contents for Trama
Page 1: ...Instruction Manual Mod 452 A ...
Page 4: ......
Page 5: ......
Page 6: ......
Page 44: ...38 33 Annexes Flow chart 1 Normal activation phase 1 ...
Page 45: ...39 Flow chart 1 Normal activation phase 2 ...
Page 46: ...40 Flow chart 2 Disconnect the unit ...
Page 47: ...41 Electrical diagram of the Free Standing Fire unit ...
Page 49: ...42 ...
Page 50: ......