12
12
Disabling
•
The turn off sequence is performed by pressing the start/stop key for 3 seconds.
•
Until completion of this phase the display will show the message “desactivação” (deactivation). The
extractor will remain active until a fume temperature of 40°C is reached, to ensure that all the fuel is
completely burned.
13
Recommendations on using this unit
•
Ensure that the unit is properly connected to the power mains using the 230V AC power cable.
•
Check if the pellet reservoir is supplied with pellets. Inside the pellet reservoir is a safety grid to prevent
users from reaching the worm screw.
•
Always check if the burner is not obstructed before igniting the unit.
THE UNIT'S COMBUSTION CHAMBER IS MADE OF IRON PLATE COATED WITH
HIGH TEMPERATURE RESISTANT PAINT, WHICH RELEASES FUMES DURING THE
FIRST BURNING SESSIONS DUE TO THE CURING OF THE PAINT.
•
Please make sure the room where the unit is installed has adequate air circulation; otherwise, the unit
will not work properly. For this reason, you should consider if there are other air-consuming heating
appliances in the room (e.g. gas units, braziers, extractors, etc.) as these should not be used
simultaneously with this unit.
•
You should not turn the stove off and on intermittently, as this could damage the unit's electronic and
electric components.
•
Even though the unit is grounded, do not touch the unit with wet hands; the improper handling of the
unit may cause an electric discharge. If you notice any electrical problems, please contact your person
who performed the installation.
•
The unit should only be disconnected after its full stop. Make sure that the display shows “Off” before
disconnecting the unit. If necessary, unplug the power cable from the power socket.
•
Never open the door when the unit is still connected to the power socket or during its operation. If you
need to open the door, disconnect the unit and allow it to cool down completely.
Summary of Contents for Trama
Page 1: ...Instruction Manual Mod 452 A ...
Page 4: ......
Page 5: ......
Page 6: ......
Page 44: ...38 33 Annexes Flow chart 1 Normal activation phase 1 ...
Page 45: ...39 Flow chart 1 Normal activation phase 2 ...
Page 46: ...40 Flow chart 2 Disconnect the unit ...
Page 47: ...41 Electrical diagram of the Free Standing Fire unit ...
Page 49: ...42 ...
Page 50: ......