39
Flowserve US Inc.
SIHI
dry
dry
dry
dry
Standard
Standard
Standard
Standard M Series
Dry Running Vacuum Pump
Issue Date: November 21, 2016 Copyright:
FLOWSERVE SIHI Pumps Rev 1
7.2.1
Specification Flange & Nozzle Force / Torque
Permissible forces on branches and permissible moments for suction
and discharge outlet flange of the pump. If different point forces are
existing at the same time, the components of the resultants of these
forces may not exceed the permissible values of each direction of
force. If these requirements are not to meet, tightness and durability
cannot be warranted
Figure 14: Flange Force &
Torque Process Connection
Permissible forces on branches and permissible moments for cooling
water inlet and outlet flange of the pump. If different point forces are
existing at the same time, the components of the resultants of these
forces may not exceed the permissible values of each direction of
force. If these requirements are not to meet, tightness and durability
cannot be warranted – Option: SIHIdry
Base Frame allows to detach
forces and torques from branches.
Cooling W ater Inlet
Cooling W ater Outlet
Fx
F
Y
F
Z
F
XD
F
Y
D
F
ZD
55lb
55lb
55lb
15lb
15lb
15lb
M
X
M
Y
M
Z
M
XS
M
YS
M
ZS
50lb ft
50lb ft
50lb ft
25lb ft
25lb ft
25lb ft
Figure 15: Flange Force &
Torque Cooling Connection
Suction Side Flange
Discharge Side Flange
F
XS
F
Y
F
ZS
F
XD
F
Y
F
Z
97lb
97lb
97lb
72lb
72lb
72lb
M
XS
M
Y
M
ZS
M
XD
M
YD
M
ZD
105lb ft
105lb ft
105lb ft
0
75lb ft
0
75lb ft
0
75lb ft
Summary of Contents for SIHI dry Standard H Series