7.2 Pipework
Caution! Improper pipe installation may harm the vacuum
pump system.
Therefore:
Pipelines must be connected to the vacuum system
as per specifications in the “Forces and Moments”
Figure 14.
Lay the pipelines in such a way that thermal
expansions do not cause undue forces and moments
on connections in joint of pipelines.
Use compensators if required.
Avoid sudden changes in pipe diameters and
directions.
Tapered pieces shall be used to change pipe
diameters.
Prevent surges of water or other liquid from getting
into the suction piping of the pump.
Ensure that pipelines are cleaned before installing the
pump stand.