MN301905 Rev A
23
|
Install Sensor (continued)
Step Three
LR46 PARABOLIC ANTENNA PREPARATION
The LR46 Series parabolic antenna (only) may be removed from the sensor to allow a flange or reducer
bushing accessory being attached to the 1 ½” NPT mounting threads and/or, the antenna may be inserted from
within the inside of the tank through the bottom of an existing fitting (where the base of the antenna is too wide
to pass through the fitting from the top). Referencing the illustrations, follow the below steps to disconnect,
mount and reattach the antenna.
1) Loosen and remove the tri-clamp connector.
2) Carefully remove the antenna.
3) Insert the antenna through the bottom of the flange.
Note:
If doing so from the inside of the tank, make
sure to secure it, so as to prevent the parabolic antenna from falling into the tank.
4) Connect the sensor to the parabolic antenna socket and reattach the tri-clamp connector.
5) Attach the sensor to the fitting as necessary.
Add a Flange to the Parabolic Antenna
Uncrew
Tri-Clamp
Remove
Parabolic
Insert
Flange
Connect Antenna
to Sensor, Attach
Screws
Thread Sensor to
Reducer Bushing
FLANGE RISER INSTALLATION
When installing the sensor on a flange with a riser (or any fitting that is tall and narrow), the antenna must
protrude at least 0.4” (10mm) from the bottom of the riser.
Antenna Extension
LR46 Series Shown
The sensor can be installed within the riser as long as the media has a strong
reflective property (dielectric constant) providing a strong echo return. The
below information describes the maximum distance that the antenna can be
recessed within a riser based on the diameter and height of the fitting.