6 Installation
FLUXUS G809
6.2 Transducers
47
UMFLUXUS_G809V2-2EN, 2020-06-25
• Repeat the steps to fix the second rail, see Fig. 6.32.
Step 5: Installation in the transducer mounting fixture Variofix L
• Press the transducers firmly into the transducer mounting fixture in the covers until the transducers are tightly fixed. The
transducer cables show in opposite directions, see Fig. 6.33.
• Adjust the transducer distance displayed by the transmitter, see Fig. 6.34.
• Fix the transducer cables with the strain relief clamp to protect them from mechanical strain, see Fig. 6.34.
• Stick coupling foil (or some coupling compound for a short-term installation) on the contact surface of the transducers.
The coupling foil can be fixed to the contact surface with some coupling compound.
• Put the covers with the transducers on the rails.
• Correct the transducer distance, if necessary.
Fig. 6.31: Ratchet clasp with tension strap
1 – sense of rotation
2 – edge
3 – lever
4 – clasp screw with slot
Fig. 6.32: Pipe with 2 rails
Notice!
The arrows on the transducers and the covers have to point in the same direction.
Fig. 6.33: Installation of the transducers in the covers
1 – cover
2 – transducer clamping fixture
1
2
4
3
4
1
2