manual – force
IQ
22
www.flexiforce.com
22
2)
auto open:
This will open the door automaticly after the same delay as "auto close"
Warning:
"Auto open" is a test function. Only use for testing!
3: Partial open:
If you push 2x the up botton the door will stop at this point
•
Use
or
to adjust to the desired position.
•
Press
twice to confirm and save the desired position.
•
Press
to return to the main menu.
•
Press once more to return to the maneuvering mode.
2x = reduced opening. Push 1 x
by reduced opening and the door will fully open
(
Not possible with remote control button)
4
R e la y s :
Use the
buttons to select the "Relays" you want to adjust (relay R1, R2, R3).
In the "Relay type" menu item you can select and adjust the following parameters:
•
Inactive
:
to deactivate relay
•
End position
:
for contact (permanent or blink) on end position top, bottom or both.
•
Movemen
t:
for contact (permanent or blink) while the door is moving
up, down or both.
With pre‐run option.
•
Electrical lock
:
optional for electrical lock ( see page 32)
•
Brake
:
to set release delay in ms
•
Radio
:
not in use
•
Ready for work**.
to select one or more safety edges to switch the relay (see table below)
•
Auto close
:
to set time the warning sign has to go on before the door is closing
Press
to confirm and save.
Press
to return to the main menu.
Press once more to return to
maneuvering mode.
Summary of Contents for ForceIQ Force100XC
Page 1: ...forceIQ manual manual version 3 0 software version 1 147 c 1 DEF5000 EN ...
Page 34: ......
Page 35: ...manual forceIQ 35 www flexiforce com 34 Appendix 6 1 Additional function terminals ...
Page 36: ...manual forceIQ 36 www flexiforce com 35 Terminal group A Terminal group B ...
Page 37: ...manual forceIQ 37 www flexiforce com Terminal group C Terminal group D ...