3.4.2
Motor setup
Use the or buttons to select one of the following menu items:
1) Motor direction
2) Encoder direction
3) Motor controller
4) Limit sw. type
5) Lift force detection
6) Inv. profile up
(
Only for inverter operator
)
7) Inv. profile down
(
Only for inverter operator
)
8) Fu profile boost
(
Only for inverter operator
)
1) Motor direction
: Use the or button to change the motor direction to "left" or "right". Press
twice to confirm.
2)
Encoder direction:
Use the or buttons to change the encoder direction to "Clockwise" or "Anti‐
clockwise. Press twice to confirm.
3) Motor controller:
Use the or buttons to choose between "Contactor relay" and "Inverter rue"
Press
twice to confirm.
Use
"
Contactor relay
"
for Force operators. Choose "Inverter rue" for frequency converters
4) Limit sw. type:
Use the or buttons to choose between several limit switch types. Press twice to
confirm.
For the force70/100/140 control unit choose "Kostal
"..
If you are not sure what kind of limit switch you have to
use, contact your operator supplier.
5) Lift force detection:
As default the lift force detection is disabled. To prevent the door from being able
to lift a person, the lift force detection shall be activated and adjusted to make the door weaker.
To set the lift force detection, navigate to the "Lift force det." menu item and press to select the
menu item.
•
Navigate to "Lift force det. Test drive" Press . Hold‐to‐run the door down to closed position.
Then run up to fully open position in hold‐to‐run mode uninterrupted, to record the normal door
run (plot).
•
Navigate to "Lift force det. up". Press and the display shows "up disabled".
With the UP and DOWN button one can enable and increase the lift force detection from 0,%
(disabled) to 20% (strongest). Recommended is to start at 5%.
Press to confirm selected value.
•
Press
to return to the main menu. Press once more to enter the manoeuvring mode.
•
Now you can verify if your setting is acceptable in the upwards direction. If the door is too strong
or too weak repeat step 2 and 3, then verify the current value.
NOTE! The door runs a while to detect the weight.
Summary of Contents for ForceIQ Force100XC
Page 1: ...forceIQ manual manual version 3 0 software version 1 147 c 1 DEF5000 EN ...
Page 34: ......
Page 35: ...manual forceIQ 35 www flexiforce com 34 Appendix 6 1 Additional function terminals ...
Page 36: ...manual forceIQ 36 www flexiforce com 35 Terminal group A Terminal group B ...
Page 37: ...manual forceIQ 37 www flexiforce com Terminal group C Terminal group D ...