manual – force
IQ
21
www.flexiforce.com
21
3.4.7. Special setup
Use the
buttons to select one of the following menu items:
1) Auto close
2) Auto open
3) Partial open
4) Relays
5) Traffic light
6) CDM6
7) Door control mode
8) External buttons
1)
Auto close:
This will automatically close the door after the set delay.
Use the
buttons to select one of the following menu items:
To set auto close :
•
Enabled
•
Close delay (use
to set time, unlimited means the timer is on but isn't counting)
•
Trig. Auto close disabled
•
Max emergn rev. (use
to set max. number of reverse after safety edge is triggered, after
that number "auto close" stops)
•
to confirm to confirm and safe
•
Press to return to the main menu.
•
Press once more to return to the maneuvering mode.
To set auto close after trigger:
•
Enabled
•
Close delay (use
to set on unlimited)
•
Trig. Auto close Enabled
•
Clearing time (use
to set time that the door close after trigger)
•
Choose kind of trigger
•
Max emergn rev. (use
to set max. number of reverse after safety edge is triggered, after
that number "auto close" stops)
•
to confirm and save
•
Press to return to the main menu.
•
Press once more to return to the maneuvering mode.
Only photocell 1 can work as a trigger for automatic closing
Summary of Contents for ForceIQ Force100XC
Page 1: ...forceIQ manual manual version 3 0 software version 1 147 c 1 DEF5000 EN ...
Page 34: ......
Page 35: ...manual forceIQ 35 www flexiforce com 34 Appendix 6 1 Additional function terminals ...
Page 36: ...manual forceIQ 36 www flexiforce com 35 Terminal group A Terminal group B ...
Page 37: ...manual forceIQ 37 www flexiforce com Terminal group C Terminal group D ...