7.3 Hydraulic connections
From the “Manual-mode” in the controller menu, a testing routine can be triggered to check if the
device is set up correctly and working accordingly. Each actuator (valve) can be operated separately
with a maximum run-time of 2 minutes.
The mains water and sealed system connection to the unit must be made using the
flexible hoses with isolation valves provided.
The drain always has to be connected. There are 3 options to connect the drain:
•
With a 22mm copper pipe
The plastic nut provided will secure the pipe in place and create a sealed connection
•
With a 32mm push- fit PP pipe
The O-ring provided on the tundish will create a sealed connection with the pipe if positioned in
the lower groove on the tundish, see image below.
•
With a 32mm solvent weld PP pipe
The O-ring provided on the tundish will create a sealed connection with the pipe if positioned in
the higher groove on the tundish, see image below.
Drain connection options
32 mm
push-
fit
32 mm
solvent
weld
Min drop dimension
120 mm
Always connect the drain-pipe
Abflussrohr immer anschließen!
Sluit altijd een afvoerleiding aan!
Raccordez toujours le tuyau d’évacuation!
22 mm copper
Connection
Summary of Contents for FlexFiller Direct G4
Page 1: ...www flamcogroup com manuals FlexFiller Direct G4 ENG Installation and operating manual...
Page 33: ...We reserve the right to change designs and technical specifications of our products 33 ENG...
Page 34: ...Manual FlexFiller Direct G4 34...
Page 35: ...We reserve the right to change designs and technical specifications of our products 35 ENG...