Fisher & Paykel ICON Use And Care Manual Download Page 19

185046221 

R

EV 

2013-01 

© 

2013

 Fisher 

Paykel 

Healthcar

Limited

 

Manufacturer

   Fisher & Paykel Healthcare Ltd, 

15

 Maurice Paykel Place, East Tamaki, Auckland

 2013

, PO Box 

14 348,

 Panmure, 

Auckland 

1741

, New Zealand Tel: +

64 9 574 0100

 Fax: +

64 9 574 0158

 Email: [email protected] Web: www.fphcare.com 

Australia

 Fisher & Paykel Healthcare Pty Limited, 

36-40

 New Street, PO Box 

167

, Ringwood, Melbourne, Victoria 

3134

, Australia 

Tel: +

61 3 9879 5022 

 Fax: 

+61 3 9879 5232

  

Austria 

Tel: 

0800 29 31 23

 Fax: 

0800 29 31 22

  

Benelux

 Tel: +

31 40 216 3555

 

Fax: +

31 40 216 3554

  

China

 Tel: +

86 20 3205 3486

 Fax: +

86 20 3205 2132

  

France

 Tel: +

33 1 6446 5201

 Fax:

 +33 1 6446 5221

 

Germany

 Tel: +

49 7181 98599 0

 Fax: +

49 7181 98599 66

  

India

 Tel: +

91 80 4284 4000

 Fax: +

91 80 4123 6044

 

Irish Republic

 Tel: 

1800 409 011

  

Italy

 Tel: +

39 06 7839 2939

 Fax: +

39

 

06 7814 7709

  

Japan

 Tel: +

81 3 3661 7205 

 

Fax: +

81 3 3661 7206

  

Northern Ireland

 Tel: 

0800 132 189

  

Spain

 Tel: +

34 902 013 346

 Fax: +

34 902 013 379

 

Sweden

 Tel: +

46 8 564 76 680

 Fax: +

46 8 36 63 10 

 

Switzerland

 Tel: 

0800 83 47 63

 Fax: 

0800 83 47 54 

 

Taiwan

 Tel: +

886 2 8751 1739

 Fax: +

886 2 8751 5625

  

Turkey

 

Fisher Paykel Sağlık Ürünleri Ticaret Limited Şirketi,  

P.O. Box 06371 Ostim,  Alinteri Bulvari 1161/1 Sokak No. 12-14, Ankara, Turkey

 Tel: +

90 312 354 34 12

 Fax: +

90 312 354 31 01 

UK

 

 

Fisher & Paykel Healthcare Ltd, Unit 

16

, Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL

6

 

7

BU, UK 

Tel: +

44 1628 626 136

 Fax: +

44 1628 626 146

  

USA/Canada

 Tel: 

1800 446 3908

 or +

1 949 453 4000

 Fax: +

1 949 453 4001

Summary of Contents for ICON

Page 1: ...Use and Care Manual ...

Page 2: ... F P ICON Menu System A 4 Simple Mode 1 On Off and Ramp A 4 2 Humidity A 4 3 Sleep Data A 4 Advanced Mode 4 On Off and Ramp A 5 5 Humidity A 5 6 Alarm On Off A 5 7 Alarm Time A 6 8 Alarm Volume A 6 9 Clock Time A 6 10 Brightness A 6 11 Sleep Data A 7 12 SensAwake On Off A 7 13 User Preferences A 7 13i Flight Mode A 8 13ii Display Pressure A 8 13iii Altitude Adjustment A 8 3 Communicating Sleep Dat...

Page 3: ...led water up to the maximum water line which is marked on the side of the Water Chamber CAUTION Do not use the device without a Water Chamber Do not use hot water and water should be replaced before each use IMPORTANT The Water Chamber cannot be disassembled To replace the Water Chamber the arrow on the circular chamber grip should face toward the Elbow Fit the Chamber Lid by lining up the large d...

Page 4: ...rt Breathing Tube come together with the electrical connectors on the Elbow Please refer to Oxygen Elbow user instructions if attaching an Oxygen Elbow From the Home Screen a quick press to the SmartDial will start therapy The Home Screen will light up and the clock face of the Menu System will rotate to indicate therapy is starting If Ramp is required press the SmartDial again and hold for 3 seco...

Page 5: ... setting is Humidity level 4 If using without water or where low power consumption is required e g for aircraft and trucking use set the humidity level to 0 3 3 Sleep Data Press and hold the SmartDial for 7 seconds to access the Sleep Data setting Turn the SmartDial to scroll through each of the following statistics Total Compliant Hours Average Compliant Hours over the last 30 nights Press the Sm...

Page 6: ...he humidity level cannot be adjusted if Flight Mode is set to on The Boost control offers three additional levels 1 2 3 to optimize the Humidity setting Press and hold the SmartDial for 3 seconds while in the Humidity setting and the Boost symbols will appear Turn to select low 1 medium 2 or high 3 and press again to accept the change CAUTION The Boost control should only be used in extreme situat...

Page 7: ...to accept the change To adjust the click volume of the SmartDial press and hold for 3 seconds while in the Alarm Volume setting The Volume symbol will be present turn to select the desired volume and press again to accept the change 9 9 Clock Time Turn the SmartDial to the Clock Time setting and press to enter Turn the SmartDial to select the hour minutes 12 hr or 24 hr time After each selection p...

Page 8: ...apsed since therapy commenced Check Sum AHI for last 30 7 and 1 nights Leak for last 30 7 and 1 nights 90th percentile pressure for last 30 7 and 1 nights SensAwake for last 30 7 and 1 nights Exit the Sleep Data setting NOTE A symbol will appear on the Home Screen when the sleep data is within the compliance requirements Once CMS requirements have been met the data within the CMS sub menu will sto...

Page 9: ...me Screen Time is the default setting however this can be changed to show pressure cmH2O or hPa if required Turn the SmartDial to the Display Pressure setting and press to enter Turn to select On or Off and press again to accept the change If a different unit of measure is required press the SmartDial and hold for 3 seconds Turn the SmartDial to select either cmH2O or hPa and press again to accept...

Page 10: ... USB Port of a computer connected to the Internet The first time you insert the InfoUSB 2 into your computer open Windows Explorer and navigate to the drive called FPHCARE 1 To install an InfoUSB detector on your computer open this folder and double click on the Setup exe file Follow the on screen instructions Upon successful installation of the InfoUSB 2 application and upon detection of an InfoU...

Page 11: ...er Empty the vinegar solution and rinse the Water Chamber thoroughly with water Disconnect the Elbow from the device and the Outlet Seal can be easily removed by lightly pushing it from the back of the device into the Water Chamber housing The Elbow and the Outlet Seal can be cleaned and washed with mild dishwashing detergent then rinsed and dried Please place the Outlet Seal before the Elbow in s...

Page 12: ...ith respiratory failure or chronic obstructive pulmonary disease The safety and effectiveness of the auto adjusting device has not been established in patients with congestive heart failure obesity hypoventilation syndrome or central sleep apnea 3 1 2 Adverse effects Nosebleeds ear and sinus discomfort may occur from the use of positive pressure therapy 3 2 Warnings 3 2 1 To avoid electric shock f...

Page 13: ...ternatively consult your healthcare provider Do not block the flow through the device as this may cause the motor to overheat Do not block the exhaust flow holes of the mask as they are designed to allow a continuous flow of air out of the mask and if blocked CO2 re breathing may occur In the event of power failure machine malfunction or if the device is turned off remove the mask immediately as t...

Page 14: ... water damage to the device Remove the Water Chamber from the device before filling Do not fill the Water Chamber above the maximum level Do not move carry transport or store the device with water in the Water Chamber 3 3 2 General Only use the device within the Operating Conditions specified in Section 2 Part 4 Position the device so the power cord connection to the power supply is easily accessi...

Page 15: ...4 5 Dynamic Pressure Stability Breath Rate BPM Test Pressure Pmin 4 0 cmH2 O Pmin 1 4 Pmax Pmin 8 0 cmH2 O Pmin 1 2 Pmax Pmin 12 0 cmH2 O Pmin 3 4 Pmax Pmin 16 0 cmH2 O Pmin 20 0 cmH2 O Novo Dynamic Pressure Stability cmH2O 10 0 76 0 84 0 90 0 99 1 04 15 0 76 0 84 0 91 0 99 1 04 20 1 16 1 22 1 28 1 38 1 44 Auto Premo Dynamic Pressure Stability cmH2O 10 0 13 0 16 0 22 0 28 0 33 15 0 27 0 26 0 31 0 ...

Page 16: ...00 F 38 C NOISE LEVEL Sound Pressure Level 29 dBA Average Sound Power Level 37 dBA WATER CHAMBER VOLUME 420 mL up to the maximum fill line STANDARDS COMPLIANCE IEC60601 1 1988 A1 A2 AS NZS 3200 1 0 1998 EN60601 1 1990 A1 A2 UL60601 1 2003 DATA RECORDING The InfoUSB records up to 365 days of summary efficacy data 7 days of detailed efficacy data AHI Leak Pressure and Leak data 50 Hz as well as cumu...

Page 17: ... to activate ThermoSmart Technology Part may vary depending on country 6 DEVICE AND CONSUMABLES DISPOSAL INSTRUCTIONS Device Disposal Instructions This device contains electronics Please do not discard as regular rubbish Dispose of electronics according to local guidelines Consumable Disposal Instructions Place the mask Breathing Tube and Water Chamber in a rubbish bag at the end of use and discar...

Page 18: ...n ensure the InfoUSB is inserted into the USB Port of the device The Heater Plate and or Water Chamber base is warm to the touch even though the device isn t being used The power supply is located directly underneath the Heater Plate and in stand by mode generates approximately 5 W of power which causes the feeling of warmth The Water Chamber is also fully insulated by the device which can cause h...

Page 19: ...any Tel 49 7181 98599 0 Fax 49 7181 98599 66 India Tel 91 80 4284 4000 Fax 91 80 4123 6044 Irish Republic Tel 1800 409 011 Italy Tel 39 06 7839 2939 Fax 39 06 7814 7709 Japan Tel 81 3 3661 7205 Fax 81 3 3661 7206 Northern Ireland Tel 0800 132 189 Spain Tel 34 902 013 346 Fax 34 902 013 379 Sweden Tel 46 8 564 76 680 Fax 46 8 36 63 10 Switzerland Tel 0800 83 47 63 Fax 0800 83 47 54 Taiwan Tel 886 2...

Reviews: