MAINTENANCE
I115SS
Rev. 001
22/12/2014
47/58
5.2.5 Battery charger technical characteristics
The battery charger should have the following characteristics:
INPUT V 230, Hz 50, A5
OUTPUT V 36, A 30
Check recommended battery specifications in section 2.3 TECHNICAL DATA SHEET.
5.2.6 BATTERY DISPOSAL
Batteries are classified as "toxic and hazardous" waste. For disposal purposes, they should be committed to
specialised, specifically authorised companies whose qualifications must be ascertained by the battery
owners. Temporary battery storage before collection by a specialised disposal company must be in line with
the following legal requirements:
A temporary storage authorisation must be obtained
The batteries must be sealed in plastic containers having capacities not lower than the volume of the
electrolyte contained in the batteries, or in any case, stored in such a way as to prevent rainwater
seeping into the storage containers.