EXTRAORDINARY MAINTENANCE
4.
Using the handle (2), in the vacuum head assembly, remove the vacuum head assembly from the
collection tank (rotating it and shifting it as indicated in the figure).
5.
Remove the fabric filter (3) from the vacuum cap, making sure not to remove the seal.
To remove the vacuum motor sponge filter, proceed as follows:
6.
Remove the motor mesh (4) turning it anti-clockwise.
7.
Remove the sponge filter (5).
8.
Replace the worn filter with the new one.
9.
Repeat the operations in reverse to reassemble.
To remove the vacuum motor cartridge filter, proceed as follows:
10.
Remove the cartridge filter (6) by rotating it anticlockwise.
11.
Replace the worn filter with the new one.
13.
Repeat the operations in reverse to reassemble.
WARNING: It is advisable to pay attention to the direction of filtration, the mesh in the
filter should be positioned opposite the vacuum motor.
3.
REPLACING THE EXHAUST AIR FILTER
To replace the exhaust air filter, proceed as follows:
1.
Take the appliance to its designated maintenance area.
2.
Do what is required to make sure the machine is in a safe condition (see
MACHINE SAFETY
’”).
3.
Free the vacuum head from the collection tank, using the lever (1) on the front rear part of the collection
tank, moving the lever as indicated by the arrow in the picture on the side.
WARNING: you are advised to always wear protective gloves, to avoid the risk of
serious injury to your hands.
Page 22