Chapter 5: System Software
5-39
Known Chain Pitch & Teeth
This option applies to the Encoder Calibration Routine. If you
know the conveyor chain pitch and the number of teeth per chain
link, set this function to present. If you do not know the conveyor
chain pitch and the number of teeth per chain link, set this function
to not present. When set to present you must also adjust the
Conveyor Segment Pitch and Teeth/Conveyor Segment options.
Encoder Resolution
Selects the resolution of the encoder installed in your system. The
Standard High Resolution Encoder is 500 pulse. The Ultra High
Resolution Encoder is 5000 pulse, and is required when using the
Diameter Missing Lid option.
Save Default Constants
Saves the current operating configuration to nonvolatile memory.
The constants are stored until they are overwritten by a more
recent save. To recall the settings from memory you must use the
Load Default Constants function.
To save the default constants:
1.
Press Key 5 until SAVE DEFAULT CONSTANTS appears.
2.
Press the Arrow Key to execute.
Conveyor Segment Pitch
The distance from one point on a conveyor chain segment to the
same point on the next conveyor segment. It defines the conveyor
segment pitch in tenths or millimeters
Teeth/Conveyor Segment
Defines the number of sprocket teeth on the drive sprocket that
contact the chain segment. The typical value is 2, however some
conveyors may have a value of 1.
Calibrate Encoder
Initiates the encoder calibration routines. For more information on
this function, see
Chapter 6: Encoder Calibration Procedures
.
Industrial Dynamics Company, Ltd.
Document 40255-0600