FT-50 Fill Level Inspector Service Manual
5-38
Rejector Type
Selects the rejector model that is controlled by the FT-50.
PLC Series Alarms
Activates or deactivates the PLC Series Alarms Function. If set to
PRESENT, the following options are activated:
•
PLC Output Pulse Width
•
Alarm Series Underfills
•
Alarm Series Overfills
•
Alarm Series Missing Lid
•
Alarm Series Bulged End
•
Alarm Series Down Can
•
Alarm Series Dia. Missing Lid
•
Alarm Series Any Other Inspections.
•
PLC Assignments
See
Chapter 9: Using a PLC With Your FT-50
for more information.
Serial Interface
Activates or deactivates the Serial Interface function. For more
information refer to the
Serial Communication Manual
.
External Trigger Logic
External Trigger Logic allows you to configure an external trigger,
such a s a manual switch, to perform either an External Reject or a
Remote Clear of Error.
External Reject: If the input TB1-20 is connected to ground (TB1-21)
the next container to pass the trigger will be rejected.
Remote Clear of Error: If the input TB1-20 is connected to ground
(TB1-21) the diagnostic error will be cleared.