Chapter 5: System Software
5-27
Alarm Missing Lid
The minimum number of consecutive missing lid rejects that will
trigger an alarm condition. The count is reset to zero when a good
container is detected. This function can alert you to seamer or
sealer malfunctions.
Alarm Bulged End
The minimum number of consecutive bulged end rejects that will
trigger an alarm condition. The count is reset to zero when a good
container is detected. This function can alert you to seamer or
sealer malfunctions.
Alarm Down Can
The minimum number of consecutive down can rejects that will
trigger an alarm condition. The count is reset to zero when a good
container is detected. This function can alert you to seamer or
sealer malfunctions, and conveyor disturbances.
Alarm Dia. Missing Lid
The minimum number of consecutive diameter missing lid rejects
that will trigger an alarm condition. The count is reset to zero
when a good container is detected. This function can alert you to
seamer or sealer malfunctions.
Alarm External Reject
The minimum number of consecutive external rejects that will
trigger an alarm condition. The count is reset to zero when the
chain of consecutive external reject signals is broken. This function
can alert you to inspection problems occurring at the external
inspection unit.
Load Default Constants
Retrieves the user defaults that were saved to memory when the
last Save User Defaults function was executed. The defaults are
loaded into active memory and become the new operating config-
uration of the machine.
To load the default constants:
1.
Press Key 5 until Load Default Constants appears.
2.
Press the Arrow Key to execute.