Chapter 10: Controller Board Dip Switches and LEDs
10-5
Switch Function Definitions
Dip Switch Pack S1
S1-1: Inspection Logic
Switches the fill level inspection logic between underfill and
overfill. All fill level text is changed to reflect the current logic. The
default is underfill.
S1-2: Software Write Protect
Enables or disables the write protect function. When disabled the
Save Default Constants function is removed from the function
menu. The default is enable.
S1-3: Speed Tracking
Switches between variable and fixed speed tracking. Variable
speed tracking is used with the High Resolution Encoder on lines
that run at more than one speed. Fixed speed tracking is used on
single speed lines and do not use the High Resolution Encoder. For
fixed lines the encoder pulse is simulated by the inspection unit’s
software. The default is variable.
S1-4: Languages
Switches between the main display language and the secondary
display language. When the secondary display language is
selected, a list of secondary languages appears in the Language
Options Menu. The default is English.
S1-5: System Configuration
Switches the system between configuration mode and standard
mode. When active this mode activates various options
throughout the software option menus. The default is off.
S1-6: Not Used
S1-7: Not Used
S1-8: Password
Enables or disables the password protect function. The default is
disabled.
Industrial Dynamics Company, Ltd.
Document 40255-0600