FCP-300/FCP-300ECS Manual —
P/N LS10145-002FK-E:A 3/12/2021
69
Section 7: Fike and SWIFT SLC Device Installation
7.1 List of Fike SLC Devices
Table 7.1 lists the available Fike SLC devices that can be used with the control panel. For more information, refer to the Device Installa-
tion Instructions (packaged with the device).
7.2 SWIFT Wireless SLC Devices
The FIK-W-WGI Wireless Gateway acts as a bridge between a group of wireless fire devices and an SLC loop on the FCP-300. It is
powered by the SLC loop or it is powered by a regulated, external 24VDC UL-listed power supply. The available wireless devices
include a photo detector, a heat detector, a fixed-temperature heat detector, a rate-of-rise detector, an ACCLIMATE detector, a pull sta-
tion, a monitor module, and a relay module. For the updated details about the wireless devices, the System setup and the operation, refer
to the SWIFT
®
Smart Wireless Integrated Fire Technology Manual, Part Number: LS10036-000FK-E for more information.
7.3 Maximum Number of SLC Devices
The FCP-300 supports Fike wireless SLC devices. The maximum number of SLC devices per panel is 300. The number of SLC expand-
ers is limited only by the SBUS bandwidth, point count, and 1A SBUS current limit. The device support is as follows:
•
Fike Devices- The FCP-300 supports a total of 300 Fike points. The SLC points can be all sensors or all modules or any
combination of modules and sensors.
•
Fike Wireless Devices–A SWIFT Gateway System supports up to 50 devices: 1 SWIFT Gateway and up to 49 (in any combination)
wireless detectors and monitor modules. Multiple Gateways can be used. See the SWIFT Manual P/N LS10036-000FK-E for more
information.
7.4 Wiring Requirements for SLC Devices
The following information applies to the SLC devices. For additional information on the type of device you want to install, refer to the
Section that describes the type of device.
!
CAUTION: DISCONNECT POWER
TO AVOID THE RISK OF ELECTRICAL SHOCK AND DAMAGE TO THE UNIT, POWER SHOULD BE OFF AT THE
CONTROL PANEL WHILE INSTALLING OR SERVICING.
Part Numbers
Model Name/Description
Install Sheet PN
FIK-2351
Photoelectric smoke detector
I56-6632
FIK-2351T
Photoelectric smoke detector with thermal (135°F)
I56-6633
FIK-2351R
Photoelectric replacement smoke detector with remote test capability in DNR
I56-6634
DNR/DNRW
Duct smoke detector housing. Non-relay (photo sold separately)
I56-3051
FIK-5351
Fixed temperature thermal detector (135°F)
I56-6635
FIK-5351R
Rate-of-rise thermal detector with 135° fixed temperature
FIK-5351H
Fixed high temperature thermal detector (190°F)
FIK-FC351
Multi-criteria fire CO detector
I56-6637
FIK-2351TIR
Multi-criteria PTIR detector
I56-6639
FIK-PULL-SA
Addressable single action pull station
I56-6959
FIK-PULL-DA
Addressable dual action pull station
I56-6958
FIK-M500X
Fault isolator module
I56-6897
ISO-6
Six Fault isolator module
I56-4096
FIK-M500M
Monitor module
I56-6671
FIK-M501M
Mini monitor module
I56-6673
FIK-M500DM
Dual input monitor module
I56-6672
FIK-IM-10
10 input monitor module
I56-6893
FIK-M500R
Relay module
I56-6674
FIK-CR-6
Six circuit relay module
I56-6894
FIK-M500MR-2
Multi module with 2 relay outputs & 2 monitor inputs
I56-6895
FIK-M502M
Zone interface module
I56-6676
FIK-CZ-6
Six zone interface module
I56-6896
FIK-M500S
Supervised control module
I56-6675
FIK-SC-6
Six circuit supervised control module
I56-6891
FIK-W-WGI
Wireless gateway module
LS10036-000FK-E
B200S-WH
/ IV
Intelligent Sounder base.
I56-3387
B200S-LF-WH / IV
Low Frequency Sounder Base
I56-4151
B300-6/ -IV
6” Plug-in Detector Base
I56-6566
B224RB-WH / IV
6" relay base
I56-3737
B501-BL/-IV/-WHITE
4" Plug-in Detector Base
I56-0357
Table 7.1 Fike IDP SLC Devices