16
6.4 Internal Function Table
No.
Description
Parameters/Note
Default =
**
F1
Analogue to Digital
(AD) Value
Press
[Print/M+]
or
[Tare]
to set the offset value to zero when unloaded. Then add load to observe the span value of
load applied.
When ADC is more than 1 million. W
1
sign appears. Actual ADC is = 1 million + the ADC value being
displayed.
When ADC is more than 2 million. W
2
sign appears. Actual ADC is = 2 million + the ADC value being
displayed.
When ADC is more than 3 million. Both W
1
& W
2
sign appear. Actual ADC is = 3 m the ADC value
being displayed.
Press
[Zero]
to quit to F1.
F2
All Segment Check
Lit up all display segments, indication, and backlight colors. Check for missing segments and backlight brightness & color
ratio.
Press
[Zero]
to quit to F2 or
[Check]
to show current battery voltage.
F3
Capacity, Division &
Default Weight Unit
Display basic metrology characteristics (capacity, division, and weight unit). The value displayed in the format of: -
•
Max + 1e for single interval mode.
•
Max
1
+ e
1
and Max
2
+ e
2
for dual weighing range/interval mode.
Press
[Zero]
to quit to F3.
F4
Date Format & Value
DD/MM/YY
** YY/MM/DD
MM/DD/YY
•
Press
[Unit]
or
[MR]
to change date format and press
[Print/M+]
to confirm.
•
Press
[Print/M+]
to check the current date value.
•
To adjust date value, input date value and press
[Print/M+]
to confirm.
•
Instrument will then display the date value inputted into week and day number (0 ~ 6 for Sunday ~ Saturday) of the year value inputted.
•
Select Date Output Type: - 2 parameters are available: -
➢
Date = Normal date format as per input above.
➢
Week = WWYYDD format. WW = week number; YY = year value; DD = weekday (Monday = 01… Sunday = 07).
F5
Time
HH:MM:SS in 24-hour format