93
Appendix T: - Production Settings PLU Saving Commands
Production Settings PLU saving commands format as below: -
a.
Start String
*
“asterisk” (Hex code 02A), followed by
b.
Command code as shown on below table (all commands are case sensitive), followed by
c.
Parameters listed on the below table. Always insert semicolon (;) in front of each parameter, followed by
d.
End String
#
“number sign” (Hex code 23).
Notes: -
For RS485 communication, add @xx before start string.
xx = machine ID number set in F18.
T.1 Command Description Table
Start
String
Command Code
(Note T1)
Parameter
End String
*
S1 or S2 or S3
LP
;d1;d2;d3;d4;d5;d6;d7;d8;d9;d10;d11;d12;d13;d14;d15
#
Note T1
: -
•
S1 = command for operation with weight unit = kg.
•
S2 = command for operation with weight unit = g.
•
S3 = command for operation with weight unit = lb.
T.2 Parameter Description Table
Parameter #
Description
Parameter
d1
PLU #
01 ~ 99
d2
Customer Code
1~18-digit (; * # not accepted). Blank = Nothing
d3
Customer Description
Maximum 30 characteristics (; * # not accepted). Blank = Nothing
d4
Product Code
1~18-digit (; * # not accepted). Blank = Nothing
d5
Product Description
Maximum 30 characteristics (; * # not accepted). Blank = Nothing