1.
Make sure that Note is set to On in F11.
2.
During operation status, press
[Set]
.
3.
Pressing
[Unit]
until Note appears.
4.
Press
[Print/M+]
.
5.
Instrument displays
nt.xxxx
. xxxx is the current short in effect.
6.
To change, input a new 4-digit value, then press
[Print/M+]
to save and return to normal operation.
Notes
: -
a.
the short note inputted will remain valid until changed or canceled.
b.
To clear short Note information, press
[CE]
in step
6
above.
19.4 Output & Settings for Alibi Memory & Management Report
Complete both 2 procedures below to output the management report.
1.
Define the report output UART number and report content in F33. Refer to
F33
of
Internal
Function Table
in
paragraph
6
for more information. Avoid assigning RS485 for report output
unless Machine ID (set in F18) is = blank.
2.
Define search criteria and date range in F34. Refer to
F34
of
Internal Function Table
in paragraph
6
for more information. Multiple search criteria are acceptable based on condition “AND”. For example,
Operator Code number XXXX and Produce Code YYYY. All transactions which fulfill
both
these 2
criteria will be outputted.
19.5 Totalization
Except date range “All” is selected in F34, instrument will output the totalized data of the below result at the end
of the output.
•
Total number of transactions of the date range
•
Total Net Weight
•
Total Gross Weight
•
Total Piece Count
20. Barcode Scanner & Auto Database Search
Once a customer/product code is scanned, instrument will perform auto search in various PLU databases
depends on the setting in F37.
When F37 is set to
On
: - Instrument starts searching from the Product Settings PLU database first,
then the Customer/Product Code & Description database.
When F37 is set to
Off
: - Instrument will ignore the Product Settings PLU database and do searching
in the Customer/Product Code & Description database only.
Searching Sequent & Action
Once a customer or product code is scanned: -
a.
(If F37 is set to
On
), instrument starts searching the code scanned in the Production Settings PLU
database.
If the code scanned exists in this database, then all settings in that Production Settings PLU will
be applied immediately.
If the code does not exist in this database, instrument will then proceed to step
b
below.
b.
Instrument starts searching the Customer/Product Code & Description Quick Access PLU database.
If the code scanned exists in this database, then the description of the code scanned will be