23
10: confIGuratIon
24.
Inputs orientation
This parameter allows reversing operation of IN1 and IN2 inputs
without changing the wiring. Use in case of incorrect wiring.
Parameter size
1B
Default value
0 (default)
Available
values
0 – default (IN1 - 1st input, IN2 - 2nd input)
1 – reversed (IN1 - 2nd input, IN2 - 1st input)
25.
Outputs orientation
This parameter allows reversing operation of OUT1 and OUT2 in-
puts without changing the wiring. Use in case of incorrect wiring.
Parameter size
1B
Default value
0 (default)
Available
values
0 – default (OUT1 - 1st output,
OUT2 - 2nd output)
1 – reversed (OUT1 - 2nd output,
OUT2 - 1st output)
40.
Input 1 - sent scenes
This parameter defines which actions result in sending scene ID
and attribute assigned to them (see 9: Activating scenes). Parame-
ter is relevant only if parameter 20 is set to 2 or 3.
Parameter size
1B
Default value
0 (no scenes sent)
Available
values
1 – Key pressed 1 time
2 – Key pressed 2 times
4 - Key pressed 3 times
8 – Key hold down and key released
41.
Input 2 - sent scenes
This parameter defines which actions result in sending scene ID
and attribute assigned to them (see 9: Activating scenes). Parame-
ter is relevant only if parameter 20 is set to 2 or 3.
Parameter size
1B
Default value
0 (no scenes sent)
Available
values
1 – Key pressed 1 time
2 – Key pressed 2 times
4 - Key pressed 3 times
8 – Key hold down and key released