9
4: InstallatIon
4.2: Connection with alarm line
1. Turn off the alarm system.
2. Connect with one of the diagrams below:
Z1 Z2
AUX COM
IN2
IN1
GND
P
COM 12V
TMP TMP
NC
NC
1
2
Diagram 1: Example connection with regular alarm line
(1 – alarm sensor, 2 – alarm system hub)
COM 12V
TMP TMP
COM
R1
R2
Z1
COM AUX
IN2
IN1
GND
P
NC
NC
1
2
Diagram 2: Example connection with parametric alarm line
(1 – alarm sensor, 2 – alarm system hub)
3. Verify correctness of connection.
4. Arrange the device and its antenna in the housing.
5. Power the device.
6. Add the device to the Z-Wave network.
7. Change values of parameters:
• Connected to IN1:
»
Normally close: change parameter 20 to 0
»
Normally open: change parameter 20 to 1
• Connected to IN2:
»
Normally close: change parameter 21 to 0
»
Normally open: change parameter 21 to 1