MS6-SV-...-E-10V24
Festo – MS6-SV-...-E-10V24 – 1310b English
69
14.2
General data
Type
MS6-SV-E
Pneumatic connection 1, 2
G
½
(ISO 228)
Pneumatic port 3
G1 (ISO 228)
Type of mounting
In-line installation
With accessories
Design
Piston seat not free of overlap
Actuation type
Electric
Pilot air supply
Internal
Exhaust function
Without flow control
Position sensing principle
Solenoid piston principle
Manual override
None
Reset method
Mechanical spring
Type of control
Piloted
Valve function
3/2-way valve, monostable, closed
Pressure build-up function
Mounting position
Any
Operating medium
Compressed air in accordance with ISO 8573-1:2010
[7:4:4]
Note on operating medium
Lubricated operation possible (in which case lubricated
operation will always be required)
Ambient temperature
[°C]
–10 … +50 (0 … +50 with pressure sensor)
Temperature of medium
[°C]
–10 … +50 (0 … +50 with pressure sensor)
Storage temperature
[°C]
–10 … +50 (0 … +50 with pressure sensor)
Shock resistance
Shock test with severity level 2 according to
FN 942017-5 and EN 60068-2-27
Vibration resistance
Transport application test with severity level 2
according to FN 942017-4 and EN 60068-2-6
Operating pressure
[bar]
3.5 … 10
C value
[l/(s bar)] 19.3
b value
0.21
Standard nominal flow rate
1
>
2
[l/min]
4 300 (if p1 = 6 bar, p2 = 5 bar)
Standard nominal flow rate
2
>
3
[l/min]
9 000 (at p1 = 6 bar)
Min. standard nominal flow rate
2
>
3 in the most critical error
case
[l/min]
6 000 (if p1 = 6 bar)
Residual pressure in normal
operation
[bar]
0 (no residual pressure)
Max. residual pressure in event
of error (worst case)
[bar]
0.4 (if p1 = 10 bar and flow control valve is fully open)